My store
Settlement

The latest addition

All Commodity  Total amount:$Settlement goods

Pilot Operated Proportional Directional Control Valve - Series D31FB OBE / D41FB OBE / D91FB OBE / D111FB OBE

Category: Valve
Master Model: N/A
Drawing No.: N/A
Quantity: - + EA
Price: Inquiry
Payment: T/T, PayPal, More
Shipping Cost: To be confirmed
Inquiry Add to Wishlist
                         
If you need a specific Pilot Operated Proportional Directional Control Valve - Series D31FB OBE / D41FB OBE / D91FB OBE / D111FB OBE firmware or series. Please call or email us your request.

  Guaranteed Fitment

  Specialist Team

  Response Rate High

  Quick & Hassle Free

Parker's proven standard performance pilot operated proportional DC valves series D*1FB with onboard electronics are universally

applicable and feature progressive flow characteristics for sensitive flow rate adjustment.

Part

Nominal Size

Spool Code

Flow Rate (lpm)

Spool Position

Pilot Connection (Inlet/Drain)

Material - Seals

Electrical Connection

Function

Connection Type

Valve Option

D41FBB31FC5NF00

NG16 / CETOP 07

B31

200

Operated in position a or b

External / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBB31FC5NS00

NG16 / CETOP 07

B31

200

Operated in position a or b

External / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBB31FC5NW50

NG16 / CETOP 07

B31

200

Operated in position a or b

External / internal

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D41FBB32CC1NS00

NG16 / CETOP 07

B32

130

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBB32CC2NF00

NG16 / CETOP 07

B32

130

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBB32CC2NS00

NG16 / CETOP 07

B32

130

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBB32CC4NF00

NG16 / CETOP 07

B32

130

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBB32CC4NG00

NG16 / CETOP 07

B32

130

Operated in position a or b

Internal / internal

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBB32CC4NS00

NG16 / CETOP 07

B32

130

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBB32FC1NF00

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBB32FC1NF08

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D41FBB32FC1NG00

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBB32FC1NM00

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBB32FC1NS00

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBB32FC1VF00

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / external

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBB32FC1VS00

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / external

FPM

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBB32FC2NF00

NG16 / CETOP 07

B32

200

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBB32FC2NG00

NG16 / CETOP 07

B32

200

Operated in position a or b

External / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBB32FC2NS00

NG16 / CETOP 07

B32

200

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBB32FC4NF00

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBB32FC4NF08

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D41FBB32FC4NG00

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / internal

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBB32FC4NM00

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBB32FC4NS00

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBB32FC4VF00

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / internal

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBB32FC4VS00

NG16 / CETOP 07

B32

200

Operated in position a or b

Internal / internal

FPM

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBB32FC5NG00

NG16 / CETOP 07

B32

200

Operated in position a or b

External / internal

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE01BC1NF00

NG16 / CETOP 07

E01

100

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01BC1NG00

NG16 / CETOP 07

E01

100

Operated in position a or b

Internal / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE01BC1NS00

NG16 / CETOP 07

E01

100

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE01BC4NF00

NG16 / CETOP 07

E01

100

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01BC4NW50

NG16 / CETOP 07

E01

100

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D41FBE01BK4NF00

NG16 / CETOP 07

E01

100

Operated in position b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01CC1NF00

NG16 / CETOP 07

E01

130

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01CC1NG00

NG16 / CETOP 07

E01

130

Operated in position a or b

Internal / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE01CC1NS00

NG16 / CETOP 07

E01

130

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE01CC2NF00

NG16 / CETOP 07

E01

130

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01CC2NF08

NG16 / CETOP 07

E01

130

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D41FBE01CC2VM00

NG16 / CETOP 07

E01

130

Operated in position a or b

External / external

FPM

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBE01CC4NF00

NG16 / CETOP 07

E01

130

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01CC4NG00

NG16 / CETOP 07

E01

130

Operated in position a or b

Internal / internal

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE01CC4NS00

NG16 / CETOP 07

E01

130

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE01CC4NW50

NG16 / CETOP 07

E01

130

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D41FBE01CC4VF00

NG16 / CETOP 07

E01

130

Operated in position a or b

Internal / internal

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01CC5NF00

NG16 / CETOP 07

E01

130

Operated in position a or b

External / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01CK2NF00

NG16 / CETOP 07

E01

130

Operated in position b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01FC1NF00

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01FC1NG00

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE01FC1NS00

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE01FC1VF00

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / external

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01FC1VS00

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / external

FPM

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE01FC2NF00

NG16 / CETOP 07

E01

200

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01FC2NF08

NG16 / CETOP 07

E01

200

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D41FBE01FC2NG00

NG16 / CETOP 07

E01

200

Operated in position a or b

External / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE01FC2NM00

NG16 / CETOP 07

E01

200

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBE01FC2NS00

NG16 / CETOP 07

E01

200

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE01FC2VF00

NG16 / CETOP 07

E01

200

Operated in position a or b

External / external

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01FC4NF00

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01FC4NF08

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D41FBE01FC4NG00

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / internal

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE01FC4NM00

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBE01FC4NS00

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE01FC4NS08

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Monitor switch

D41FBE01FC4NW50

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D41FBE01FC4VF00

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / internal

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01FC4VW50

NG16 / CETOP 07

E01

200

Operated in position a or b

Internal / internal

FPM

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D41FBE01FC5NF00

NG16 / CETOP 07

E01

200

Operated in position a or b

External / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01FC5NG00

NG16 / CETOP 07

E01

200

Operated in position a or b

External / internal

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE01FC5NS00

NG16 / CETOP 07

E01

200

Operated in position a or b

External / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE01FE1NF00

NG16 / CETOP 07

E01

200

Operated in position a

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01FE2NF00

NG16 / CETOP 07

E01

200

Operated in position a

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01FE2NM08

NG16 / CETOP 07

E01

200

Operated in position a

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Monitor switch

D41FBE01FK1NF00

NG16 / CETOP 07

E01

200

Operated in position b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE01FK1NS00

NG16 / CETOP 07

E01

200

Operated in position b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE01FK2NS00

NG16 / CETOP 07

E01

200

Operated in position b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02BC1NF00

NG16 / CETOP 07

E02

100

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02BC1NG00

NG16 / CETOP 07

E02

100

Operated in position a or b

Internal / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE02BC1NS00

NG16 / CETOP 07

E02

100

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02BC2NF00

NG16 / CETOP 07

E02

100

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02BC2NS00

NG16 / CETOP 07

E02

100

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02BC2VS00

NG16 / CETOP 07

E02

100

Operated in position a or b

External / external

FPM

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02BC4NF00

NG16 / CETOP 07

E02

100

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02BC4NM00

NG16 / CETOP 07

E02

100

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBE02BC4NS00

NG16 / CETOP 07

E02

100

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02BC4NW50

NG16 / CETOP 07

E02

100

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D41FBE02BC4VM00

NG16 / CETOP 07

E02

100

Operated in position a or b

Internal / internal

FPM

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBE02BK2NS00

NG16 / CETOP 07

E02

100

Operated in position b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02CC1NF00

NG16 / CETOP 07

E02

130

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02CC1NM00

NG16 / CETOP 07

E02

130

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBE02CC1NS00

NG16 / CETOP 07

E02

130

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02CC2NF00

NG16 / CETOP 07

E02

130

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02CC2NS00

NG16 / CETOP 07

E02

130

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02CC2VS00

NG16 / CETOP 07

E02

130

Operated in position a or b

External / external

FPM

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02CC4NF00

NG16 / CETOP 07

E02

130

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02CC4NM00

NG16 / CETOP 07

E02

130

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBE02CC4NS00

NG16 / CETOP 07

E02

130

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02CC4NW50

NG16 / CETOP 07

E02

130

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D41FBE02CC4VF00

NG16 / CETOP 07

E02

130

Operated in position a or b

Internal / internal

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02CC4VG00

NG16 / CETOP 07

E02

130

Operated in position a or b

Internal / internal

FPM

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE02CC4VS00

NG16 / CETOP 07

E02

130

Operated in position a or b

Internal / internal

FPM

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02CK2NG08

NG16 / CETOP 07

E02

130

Operated in position b

External / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Monitor switch

D41FBE02FC1NF00

NG16 / CETOP 07

E02

200

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02FC1NG00

NG16 / CETOP 07

E02

200

Operated in position a or b

Internal / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE02FC1NM00

NG16 / CETOP 07

E02

200

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBE02FC1NS00

NG16 / CETOP 07

E02

200

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02FC1NW50

NG16 / CETOP 07

E02

200

Operated in position a or b

Internal / external

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D41FBE02FC1VF00

NG16 / CETOP 07

E02

200

Operated in position a or b

Internal / external

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02FC2NF00

NG16 / CETOP 07

E02

200

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02FC2NG00

NG16 / CETOP 07

E02

200

Operated in position a or b

External / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE02FC2NG08

NG16 / CETOP 07

E02

200

Operated in position a or b

External / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Monitor switch

D41FBE02FC2NM00

NG16 / CETOP 07

E02

200

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBE02FC2NS00

NG16 / CETOP 07

E02

200

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02FC2NS08

NG16 / CETOP 07

E02

200

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Monitor switch

D41FBE02FC2VS00

NG16 / CETOP 07

E02

200

Operated in position a or b

External / external

FPM

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02FC4NF00

NG16 / CETOP 07

E02

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02FC4NG00

NG16 / CETOP 07

E02

200

Operated in position a or b

Internal / internal

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE02FC4NM00

NG16 / CETOP 07

E02

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBE02FC4NS00

NG16 / CETOP 07

E02

200

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02FC4NW50

NG16 / CETOP 07

E02

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D41FBE02FC4VF00

NG16 / CETOP 07

E02

200

Operated in position a or b

Internal / internal

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02FC4VG00

NG16 / CETOP 07

E02

200

Operated in position a or b

Internal / internal

FPM

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBE02FC5NF00

NG16 / CETOP 07

E02

200

Operated in position a or b

External / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02FC5NM00

NG16 / CETOP 07

E02

200

Operated in position a or b

External / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBE02FE4NF00

NG16 / CETOP 07

E02

200

Operated in position a

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBE02FE5NF08

NG16 / CETOP 07

E02

200

Operated in position a

External / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D41FBE02FK1NS00

NG16 / CETOP 07

E02

200

Operated in position b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02FK2NS00

NG16 / CETOP 07

E02

200

Operated in position b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBE02FK4NS08

NG16 / CETOP 07

E02

200

Operated in position b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Monitor switch

D41FBR31FC4NF00

NG16 / CETOP 07

R31

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBR31FC4NG00

NG16 / CETOP 07

R31

200

Operated in position a or b

Internal / internal

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D41FBR31FC4NM00

NG16 / CETOP 07

R31

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D41FBR31FC4NS00

NG16 / CETOP 07

R31

200

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBR31FC5NF00

NG16 / CETOP 07

R31

200

Operated in position a or b

External / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBR32FC1NF00

NG16 / CETOP 07

R32

200

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBR32FC1NS00

NG16 / CETOP 07

R32

200

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBR32FC2NS00

NG16 / CETOP 07

R32

200

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBR32FC4NF00

NG16 / CETOP 07

R32

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D41FBR32FC4NS00

NG16 / CETOP 07

R32

200

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D41FBZ31FC1NF0L

NG16 / CETOP 07

Z31

200

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Hybrid valve

D41FBZ31FC1NW5L

NG16 / CETOP 07

Z31

200

Operated in position a or b

Internal / external

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Hybrid valve

D41FBZ31FC2NF08

NG16 / CETOP 07

Z31

200

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D41FBZ31FC2NF0L

NG16 / CETOP 07

Z31

200

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Hybrid valve

D41FBZ31FC4NF0L

NG16 / CETOP 07

Z31

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Hybrid valve

D41FBZ31FC4NM08

NG16 / CETOP 07

Z31

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Monitor switch

D41FBZ31FC5NF0L

NG16 / CETOP 07

Z31

200

Operated in position a or b

External / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Hybrid valve

D41FBZ32FC1NF0L

NG16 / CETOP 07

Z32

200

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Hybrid valve

D41FBZ32FC2NF0L

NG16 / CETOP 07

Z32

200

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Hybrid valve

D41FBZ32FC4NF0L

NG16 / CETOP 07

Z32

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Hybrid valve

D41FBZ32FC4NM0L

NG16 / CETOP 07

Z32

200

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Hybrid valve

D91FBB31HC1NF00

NG25 / CETOP 08

B31

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBB31HC1VF00

NG25 / CETOP 08

B31

400

Operated in position a or b

Internal / external

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBB31HC2NF00

NG25 / CETOP 08

B31

400

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBB31HC2NG00

NG25 / CETOP 08

B31

400

Operated in position a or b

External / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D91FBB31HC2NS00

NG25 / CETOP 08

B31

400

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBB31HC2NS08

NG25 / CETOP 08

B31

400

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Monitor switch

D91FBB31HC2NW50

NG25 / CETOP 08

B31

400

Operated in position a or b

External / external

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D91FBB31HC4NF00

NG25 / CETOP 08

B31

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBB31HC4NF08

NG25 / CETOP 08

B31

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D91FBB31HC4NS00

NG25 / CETOP 08

B31

400

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBB32HC1NF00

NG25 / CETOP 08

B32

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBB32HC1NF08

NG25 / CETOP 08

B32

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D91FBB32HC1NG00

NG25 / CETOP 08

B32

400

Operated in position a or b

Internal / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D91FBB32HC1NS00

NG25 / CETOP 08

B32

400

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBB32HC1VF00

NG25 / CETOP 08

B32

400

Operated in position a or b

Internal / external

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBB32HC1VS00

NG25 / CETOP 08

B32

400

Operated in position a or b

Internal / external

FPM

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBB32HC2NF00

NG25 / CETOP 08

B32

400

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBB32HC2NG00

NG25 / CETOP 08

B32

400

Operated in position a or b

External / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D91FBB32HC2NS00

NG25 / CETOP 08

B32

400

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBB32HC2VF00

NG25 / CETOP 08

B32

400

Operated in position a or b

External / external

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBB32HC2VM00

NG25 / CETOP 08

B32

400

Operated in position a or b

External / external

FPM

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D91FBB32HC4NF00

NG25 / CETOP 08

B32

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBB32HC4NG00

NG25 / CETOP 08

B32

400

Operated in position a or b

Internal / internal

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D91FBB32HC4NS00

NG25 / CETOP 08

B32

400

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBB32HC4VF00

NG25 / CETOP 08

B32

400

Operated in position a or b

Internal / internal

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBB32HC4VG00

NG25 / CETOP 08

B32

400

Operated in position a or b

Internal / internal

FPM

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D91FBE01EC1NF00

NG25 / CETOP 08

E01

250

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01EC1NF08

NG25 / CETOP 08

E01

250

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D91FBE01EC1NS00

NG25 / CETOP 08

E01

250

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE01EC1VF00

NG25 / CETOP 08

E01

250

Operated in position a or b

Internal / external

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01EC2NF00

NG25 / CETOP 08

E01

250

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01EC2NS00

NG25 / CETOP 08

E01

250

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE01EC4NF00

NG25 / CETOP 08

E01

250

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01EC4NF08

NG25 / CETOP 08

E01

250

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D91FBE01EC4NG00

NG25 / CETOP 08

E01

250

Operated in position a or b

Internal / internal

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D91FBE01EC4NM00

NG25 / CETOP 08

E01

250

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D91FBE01EC4NS00

NG25 / CETOP 08

E01

250

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE01EC4VF00

NG25 / CETOP 08

E01

250

Operated in position a or b

Internal / internal

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01HC1NF00

NG25 / CETOP 08

E01

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01HC1NG00

NG25 / CETOP 08

E01

400

Operated in position a or b

Internal / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D91FBE01HC1NM00

NG25 / CETOP 08

E01

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D91FBE01HC1NS00

NG25 / CETOP 08

E01

400

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE01HC1VF00

NG25 / CETOP 08

E01

400

Operated in position a or b

Internal / external

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01HC1VS00

NG25 / CETOP 08

E01

400

Operated in position a or b

Internal / external

FPM

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE01HC2NF00

NG25 / CETOP 08

E01

400

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01HC2NF08

NG25 / CETOP 08

E01

400

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D91FBE01HC2NG08

NG25 / CETOP 08

E01

400

Operated in position a or b

External / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Monitor switch

D91FBE01HC2NM00

NG25 / CETOP 08

E01

400

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D91FBE01HC2NM08

NG25 / CETOP 08

E01

400

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Monitor switch

D91FBE01HC2NS00

NG25 / CETOP 08

E01

400

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE01HC4NF00

NG25 / CETOP 08

E01

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01HC4NF08

NG25 / CETOP 08

E01

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D91FBE01HC4NG00

NG25 / CETOP 08

E01

400

Operated in position a or b

Internal / internal

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D91FBE01HC4NM00

NG25 / CETOP 08

E01

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D91FBE01HC4NS00

NG25 / CETOP 08

E01

400

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE01HC4VF00

NG25 / CETOP 08

E01

400

Operated in position a or b

Internal / internal

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01HC4VS00

NG25 / CETOP 08

E01

400

Operated in position a or b

Internal / internal

FPM

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE01HC5NF00

NG25 / CETOP 08

E01

400

Operated in position a or b

External / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01HC5NS00

NG25 / CETOP 08

E01

400

Operated in position a or b

External / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE01HE1NF00

NG25 / CETOP 08

E01

400

Operated in position a

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01HE2NF00

NG25 / CETOP 08

E01

400

Operated in position a

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01HK1NS00

NG25 / CETOP 08

E01

400

Operated in position b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE01HK2NF00

NG25 / CETOP 08

E01

400

Operated in position b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE01HK5VF00

NG25 / CETOP 08

E01

400

Operated in position b

External / internal

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE02EC1NF00

NG25 / CETOP 08

E02

250

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE02EC1NG00

NG25 / CETOP 08

E02

250

Operated in position a or b

Internal / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D91FBE02EC1NM00

NG25 / CETOP 08

E02

250

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D91FBE02EC1NS00

NG25 / CETOP 08

E02

250

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE02EC2NF00

NG25 / CETOP 08

E02

250

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE02EC2NS00

NG25 / CETOP 08

E02

250

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE02EC4NF00

NG25 / CETOP 08

E02

250

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE02EC4NS00

NG25 / CETOP 08

E02

250

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE02HC1NF00

NG25 / CETOP 08

E02

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE02HC1NG00

NG25 / CETOP 08

E02

400

Operated in position a or b

Internal / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D91FBE02HC1NM00

NG25 / CETOP 08

E02

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D91FBE02HC1NM08

NG25 / CETOP 08

E02

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Monitor switch

D91FBE02HC1NS00

NG25 / CETOP 08

E02

400

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE02HC1VF00

NG25 / CETOP 08

E02

400

Operated in position a or b

Internal / external

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE02HC2NF00

NG25 / CETOP 08

E02

400

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE02HC2NG00

NG25 / CETOP 08

E02

400

Operated in position a or b

External / external

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D91FBE02HC2NS00

NG25 / CETOP 08

E02

400

Operated in position a or b

External / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE02HC2NW50

NG25 / CETOP 08

E02

400

Operated in position a or b

External / external

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D91FBE02HC4NF00

NG25 / CETOP 08

E02

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE02HC4NG00

NG25 / CETOP 08

E02

400

Operated in position a or b

Internal / internal

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Standard

D91FBE02HC4NM00

NG25 / CETOP 08

E02

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D91FBE02HC4NS00

NG25 / CETOP 08

E02

400

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE02HC4NW50

NG25 / CETOP 08

E02

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D91FBE02HC4VF00

NG25 / CETOP 08

E02

400

Operated in position a or b

Internal / internal

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBE02HC4VS00

NG25 / CETOP 08

E02

400

Operated in position a or b

Internal / internal

FPM

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBE02HC5NM00

NG25 / CETOP 08

E02

400

Operated in position a or b

External / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D91FBE02HC5NW50

NG25 / CETOP 08

E02

400

Operated in position a or b

External / internal

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D91FBE02HK1NS00

NG25 / CETOP 08

E02

400

Operated in position b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBR31HC2NM00

NG25 / CETOP 08

R31

400

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D91FBR31HC2NW50

NG25 / CETOP 08

R31

400

Operated in position a or b

External / external

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Standard

D91FBR31HC4NF00

NG25 / CETOP 08

R31

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBR31HC4NM00

NG25 / CETOP 08

R31

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D91FBR31HC4NS00

NG25 / CETOP 08

R31

400

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBR32HC1NM00

NG25 / CETOP 08

R32

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Standard

D91FBR32HC1NS00

NG25 / CETOP 08

R32

400

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBR32HC2NF00

NG25 / CETOP 08

R32

400

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBR32HC4NF00

NG25 / CETOP 08

R32

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Standard

D91FBR32HC4NS00

NG25 / CETOP 08

R32

400

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Standard

D91FBZ31HC1NF0L

NG25 / CETOP 08

Z31

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Hybrid valve

D91FBZ31HC1NM0L

NG25 / CETOP 08

Z31

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Hybrid valve

D91FBZ31HC1NW5L

NG25 / CETOP 08

Z31

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V) / 4 - 20 (mA)

0 - +10 V = P-A; 12 - 20 mA = P-A

11 + PE

Hybrid valve

D91FBZ31HC2NF08

NG25 / CETOP 08

Z31

400

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D91FBZ31HC2NF0L

NG25 / CETOP 08

Z31

400

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Hybrid valve

D91FBZ31HC2NM0L

NG25 / CETOP 08

Z31

400

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Hybrid valve

D91FBZ31HC4NF0L

NG25 / CETOP 08

Z31

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Hybrid valve

D91FBZ31HC4NS0L

NG25 / CETOP 08

Z31

400

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Hybrid valve

D91FBZ32HC1NF0L

NG25 / CETOP 08

Z32

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Hybrid valve

D91FBZ32HC1NM0L

NG25 / CETOP 08

Z32

400

Operated in position a or b

Internal / external

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Hybrid valve

D91FBZ32HC1NS0L

NG25 / CETOP 08

Z32

400

Operated in position a or b

Internal / external

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Hybrid valve

D91FBZ32HC2NF08

NG25 / CETOP 08

Z32

400

Operated in position a or b

External / external

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch

D91FBZ32HC4NF0L

NG25 / CETOP 08

Z32

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Hybrid valve

D91FBZ32HC4NG0L

NG25 / CETOP 08

Z32

400

Operated in position a or b

Internal / internal

NBR

0 - ±20 (mA)

0 - +20 mA = P-B

6 + PE

Hybrid valve

D91FBZ32HC4NM0L

NG25 / CETOP 08

Z32

400

Operated in position a or b

Internal / internal

NBR

0 - ±10 (V)

0 - +10 V = P-A

6 + PE

Hybrid valve

D91FBZ32HC4NS0L

NG25 / CETOP 08

Z32

400

Operated in position a or b

Internal / internal

NBR

4 - 20 (mA)

12 - 20 mA = P-A

6 + PE

Hybrid valve

D91FBZ32HC4VF08

NG25 / CETOP 08

Z32

400

Operated in position a or b

Internal / internal

FPM

0 - ±10 (V)

0 - +10 V = P-B

6 + PE

Monitor switch