Part
|
Size
|
Certificates
|
Spool Code
|
Spool Position
|
Pilot Connection
(Inlet/Drain)
|
Seal Material
|
Voltage
|
Connection
|
Solenoid Option
|
Tube
|
Override
|
Electrical Option
|
Options
|
D61VW001C4NJP3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW001C4NJP45
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4NJP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4NJP53K
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter-out; Storke Adjustment A and B ends w/Lights
|
D61VW001C4NJPJ5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Diode
Surge Suppresor
|
Signal
Lights
|
D61VW001C4NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NJW3B
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter In
|
D61VW001C4NJW3F
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Stroke
Adjust A and B end
|
D61VW001C4NJW3K
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter out w/ Stroke Adjust A and B end
|
D61VW001C4NJW4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NJWL
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NKC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
12
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NKC4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
12
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NKG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
12
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4NKP3K
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
12
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter out w/ Stroke Adjust A and B end
|
D61VW001C4NKW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
12
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NKW1R
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
12
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Stroke
Adjust A and B End with Pilot Choke Meter In
|
D61VW001C4NKW4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
12
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NRC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24/60
VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NTC3K
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter-out with Stroke Adjust A and B End
|
D61VW001C4NTCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NTCF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C4NTPF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4NTPH
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NTPH3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C4NTW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NTWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYC3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C4NYC3F
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Stroke
Adjust A and B end
|
D61VW001C4NYC4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYC43A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C4NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYCF20
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Fast
Response
|
D61VW001C4NYCF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C4NYCF3B
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter In
|
D61VW001C4NYCF3F
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Stroke
Adjust A and B end
|
D61VW001C4NYCF3K
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter out w/ Stroke Adjust A and B end
|
D61VW001C4NYCF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYCF420
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Fast
Response
|
D61VW001C4NYCF43A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C4NYCF43K
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter out w/ Stroke Adjust A and B end
|
D61VW001C4NYCFP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Extended
with Boot
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYCP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Extended
with Boot
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYCP4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Extended
with Boot
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYET
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Explosion
Proof
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
None
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYG3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW001C4NYG3S
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Lights,
Mini Manaplug, Pilot Choke Meter Out
|
D61VW001C4NYG3W
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(mini) Double Solenoid 5-Pin w/Lights and Stroke Adjustment A and B Ends
|
D61VW001C4NYG45
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4NYG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4NYG56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001C4NYG7B
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
- Brad Harrison (12x1) Micro with Lights
|
D61VW001C4NYGF3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW001C4NYGF3S
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Lights,
Mini Manaplug, Pilot Choke Meter Out
|
D61VW001C4NYGF3W
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(mini) Double Solenoid 5-Pin w/Lights and Stroke Adjustment A and B Ends
|
D61VW001C4NYGF43S
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Lights,
Mini Manaplug, Pilot Choke Meter Out
|
D61VW001C4NYGF45
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4NYGF456
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001C4NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4NYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001C4NYGFH56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001C4NYGFP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Extended
with Boot
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4NYGFP56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Extended
with Boot
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001C4NYGP3W
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Extended
with Boot
|
Omit
- No Options
|
Manaplug
(mini) Double Solenoid 5-Pin w/Lights and Stroke Adjustment A and B Ends
|
D61VW001C4NYGP456
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Extended
with Boot
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001C4NYP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4NYPF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYPF3F
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Stroke
Adjust A and B end
|
D61VW001C4NYPF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4NYPH5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4NYW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYWF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C4NYWF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4NYWF43A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C4NYWH
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4VDC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4VJC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4VJET3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
Explosion
Proof
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
None
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C4VJG3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW001C4VJG45
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4VJGLJ56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
Plug-In
Conduit Box
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Diode
Surge Suppresor
|
Manaplug
(Mini) with Lights
|
D61VW001C4VJP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4VJP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4VJPL1P
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
DIN
with Plug
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Painted
Body
|
D61VW001C4VJPL5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
DIN
with Plug
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4VJPLJ5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
DIN
with Plug
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Diode
Surge Suppresor
|
Signal
Lights
|
D61VW001C4VJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4VJW1P
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Painted
Body
|
D61VW001C4VYC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4VYC3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C4VYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4VYCF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C4VYCH
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4VYGF3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW001C4VYGF45
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4VYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C4VYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001C4VYGF7B
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
- Brad Harrison (12x1) Micro with Lights
|
D61VW001C4VYPF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4VYPF20
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Fast
Response
|
D61VW001C4VYPF3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW001C4VYPF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4VYW3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C4VYW3K
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter out w/ Stroke Adjust A and B end
|
D61VW001C4VYWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4VYWF3K
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter out w/ Stroke Adjust A and B end
|
D61VW001C4VYWF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C4VZC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
250
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C5NJP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C5NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C5NJWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C5NTPH3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C5NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C5NYCF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C5NYG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C5NYG56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001C5NYGF3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW001C5NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C5VJP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001C5VJPLJ5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
DIN
with Plug
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Diode
Surge Suppresor
|
Signal
Lights
|
D61VW001C5VYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C5VYCF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C6NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot w/Check, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001C6NYCF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot w/Check, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001C6NYG3W
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot w/Check, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(mini) Double Solenoid 5-Pin w/Lights and Stroke Adjustment A and B Ends
|
D61VW001C6NYG561R
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot w/Check, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(mini) w/Lights and Stroke Adjust A and B ends with Pilot Choike Meter-in
|
D61VW001C6VYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot w/Check, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001D1NDP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
120
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D1NJET
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
Explosion
Proof
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
None
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D1NJP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D1NJP3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW001D1NJP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001D1NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D1NKC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
12
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D1NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D1NYG56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001D1NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001D1NYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001D1NYPF3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW001D1NYPF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001D1NYPH
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D1NYWF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D1NYWF43A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001D1VYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D1VYG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001D1VYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001D2NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
External
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D2NYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
External
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001D2NYW4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
External
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D2NYWF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
External
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D3NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot w/Check, External Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D3NYC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot w/Check, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D3NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot w/Check, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D3NYW4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot w/Check, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NJC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NJC20
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Fast
Response
|
D61VW001D4NJG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001D4NJP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NJPJ5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Diode
Surge Suppresor
|
Signal
Lights
|
D61VW001D4NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NKC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
12
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NRCH
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24/60
VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NTCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NTPH3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW001D4NTW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NTWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NUW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
98
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NYC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NYCF20
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Fast
Response
|
D61VW001D4NYCF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001D4NYCF3K
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter out w/ Stroke Adjust A and B end
|
D61VW001D4NYCF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NYCF43A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001D4NYCF43K
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter out w/ Stroke Adjust A and B end
|
D61VW001D4NYCFP3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Extended
with Boot
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001D4NYET
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Explosion
Proof
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
None
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NYG3S
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Lights,
Mini Manaplug, Pilot Choke Meter Out
|
D61VW001D4NYG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001D4NYG56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001D4NYGF3S
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Lights,
Mini Manaplug, Pilot Choke Meter Out
|
D61VW001D4NYGF456
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001D4NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001D4NYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001D4NYGH5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001D4NYP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NYPF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NYPH
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NYPH5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001D4NYPZ
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Rectified
Coil
|
Omit
- No Options
|
D61VW001D4NYPZ3C
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Rectified
Coil
|
Pilot
Pressure Reducer
|
D61VW001D4NYW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4NYWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4VDC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4VJP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001D4VYC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4VYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D4VYG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001D4VYGF456
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001D4VYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001D5NYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
External
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001D6NTWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot w/Check, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D6NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot w/Check, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001D6NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot w/Check, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001D6VYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Double
solenoid, 2 position, detent
|
Internal
Pilot w/Check, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001E1NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E1NYPF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E2NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
External
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E2NYW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
External
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E2VYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
External
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E2VYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
External
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001E4NJP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E4NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E4NKC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, Internal Drain
|
Nitrile
|
12
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E4NTW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E4NYC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E4NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E4NYG56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001E4NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001E4NYW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E4NYW4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E4NYWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001E4NYWF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001F1NDEU
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
120
VDC
|
Explosion
Proof
|
Explosion
Proof, UL/CSA
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001F1NJP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001F1NJP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001F1NJPP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Extended
with Boot
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001F1NYW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001F2VTPH5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
External
Pilot, External Drain
|
Fluorocarbon
|
240/60
- 220/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001F4NDC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001F4NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001F4NTCF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001F4NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001F4NYCF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001F4NYW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001F4VYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001F4VYCF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001F4VYCH
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H1NJP3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW001H1NYC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H1NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H1NYG1C
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug(Mini)
Single Solenoid 5-pin with Lights
|
D61VW001H1NYG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001H1NYPF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001H1VYGF1C
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug(Mini)
Single Solenoid 5-pin with Lights
|
D61VW001H2NJC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
External
Pilot, External Drain
|
Nitrile
|
24
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H2NJP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
External
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H2NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
External
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H4NJC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H4NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H4NJW4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H4NJWL
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H4NJWL4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H4NKC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
12
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H4NKG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
12
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001H4NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H4NYG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001H4NYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW001H4NYPF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H4NYWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW001H4NYWF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW001H4VJG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW001H4VKG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Blocked
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
12
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|