My store
Settlement

The latest addition

All Commodity  Total amount:$Settlement goods

Pilot Operated Directional Control Valve - D61VW Series

Category: Valve and Pump and Hydraulic Motor and Cylinder
Master Model: N/A
Drawing No.: N/A
Quantity: - + EA
Price: Inquiry
Payment: T/T, PayPal, More
Shipping Cost: To be confirmed
Inquiry Add to Wishlist
                         
If you need a specific Pilot Operated Directional Control Valve - D61VW Series firmware or series. Please call or email us your request.

  Guaranteed Fitment

  Specialist Team

  Response Rate High

  Quick & Hassle Free

D61VW directional control valves are 5-chamber, pilot operated, solenoid controlled valves.
Part Size Certificates Spool Code Spool Position Pilot Connection (Inlet/Drain) Seal Material Voltage Connection Solenoid Option Tube Override Electrical Option Options
D61VW001H4VKGF5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring offset. P to B and A to T in offset position Internal Pilot, Internal Drain Fluorocarbon 12 VDC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW001H4VYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring offset. P to B and A to T in offset position Internal Pilot, Internal Drain Fluorocarbon 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001H4VYGF5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring offset. P to B and A to T in offset position Internal Pilot, Internal Drain Fluorocarbon 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW001H4VYGF7B NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring offset. P to B and A to T in offset position Internal Pilot, Internal Drain Fluorocarbon 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug - Brad Harrison (12x1) Micro with Lights
D61VW001H4VYP NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring offset. P to B and A to T in offset position Internal Pilot, Internal Drain Fluorocarbon 120/60 - 110/50 VAC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001H5NYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring offset. P to B and A to T in offset position External Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001H5NYG56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring offset. P to B and A to T in offset position External Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW001K1NJC3C NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, External Drain Nitrile 24 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Pressure Reducer
D61VW001K1NJC3R NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, External Drain Nitrile 24 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out and Pilot Pressure Reducer
D61VW001K1NJW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K1NYW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K1NYWH NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt High Pressure, AC Only 207 Bar (3000 psi) Omit - Standard Omit - No Options Omit - No Options
D61VW001K2NJW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized External Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K2NKC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized External Pilot, External Drain Nitrile 12 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K2NTW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized External Pilot, External Drain Nitrile 240/60 - 220/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K2NYGF5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW001K2NYP NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized External Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K2NYW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized External Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K4NJP5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, Internal Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW001K4NJW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, Internal Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K4NYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K4NYGF1C3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug(Mini) Single Solenoid 5-pin with Lights, Pilot Choke Meter Out
D61VW001K4NYP NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K4NYW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K4NYWF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K4VYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, Internal Drain Fluorocarbon 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K5NJW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized External Pilot, Internal Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001K5NYGF56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized External Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW001K5NYWF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized External Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW001M2NYCF3D NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; All Ports Blocked Single solenoid, 2 position, spring offset, energized to center. Spacer on A side. P to A and B to T in offset position External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Stroke Adjust B end
D61VW003C1NJW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C1NJW3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW003C1NTCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 240/60 - 220/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C1NYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C1NYGF5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW003C1NYGFH5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt High Pressure, AC Only 207 Bar (3000 psi) Omit - Standard Omit - No Options Signal Lights
D61VW003C1VYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C1VYCF3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW003C2NYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C2NYCF20 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Fast Response
D61VW003C2NYG5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW003C2NYGF3S NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Lights, Mini Manaplug, Pilot Choke Meter Out
D61VW003C2NYW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C3NYC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot w/Check, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C3NYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot w/Check, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C4NJC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C4NJGP43W NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Extended with Boot Omit - No Options Manaplug (mini) Double Solenoid 5-Pin w/Lights and Stroke Adjustment A and B Ends
D61VW003C4NJP NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C4NJW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C4NJW43F NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Stroke Adjust A and B end
D61VW003C4NYC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C4NYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C4NYCF3F NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Stroke Adjust A and B end
D61VW003C4NYG456 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW003C4NYG56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW003C4NYG563F NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (mini) w/Lights and Stroke Adjust at A and B Ends
D61VW003C4NYGF3G NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out with Lights
D61VW003C4NYGF3S NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Lights, Mini Manaplug, Pilot Choke Meter Out
D61VW003C4NYGF3W NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (mini) Double Solenoid 5-Pin w/Lights and Stroke Adjustment A and B Ends
D61VW003C4NYGF5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW003C4NYGF56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW003C4NYGP3W NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Extended with Boot Omit - No Options Manaplug (mini) Double Solenoid 5-Pin w/Lights and Stroke Adjustment A and B Ends
D61VW003C4NYGP56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Extended with Boot Omit - No Options Manaplug (Mini) with Lights
D61VW003C4NYPF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN with Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C4NYW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C4NYW4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C4NYWF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C4NYWF3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW003C4NYWF4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C4NYWF43F NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Stroke Adjust A and B end
D61VW003C4VYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Fluorocarbon 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C4VYGF5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Fluorocarbon 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW003C4VYGFP3W NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Fluorocarbon 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Extended with Boot Omit - No Options Manaplug (mini) Double Solenoid 5-Pin w/Lights and Stroke Adjustment A and B Ends
D61VW003C4VYGP3W NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Fluorocarbon 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Extended with Boot Omit - No Options Manaplug (mini) Double Solenoid 5-Pin w/Lights and Stroke Adjustment A and B Ends
D61VW003C5NYGF5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered External Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW003C5NYGF56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered External Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW003C5VYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered External Pilot, Internal Drain Fluorocarbon 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003C6NJW43D NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; A to T and B and P Blocked Double solenoid, 3 position, spring centered Internal Pilot w/Check, Internal Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Stroke Adjust B end
D61VW003E1NYC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Single solenoid, 2 position, spring centered. P to B and A to T when energized Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW003K1NJW3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW003K1NYPF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; A to T and B and P Blocked Single solenoid, 2 position, spring centered. P to A and B to T when energized Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN with Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B1NJC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, External Drain Nitrile 24 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B1NJG7B NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, External Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug - Brad Harrison (12x1) Micro with Lights
D61VW004B1NKW4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, External Drain Nitrile 12 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B1NTPF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, External Drain Nitrile 240/60 - 220/50 VAC DIN with Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B1NYC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B1NYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B1NYPF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN with Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B1NYW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B2NJW43A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position External Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004B2NTPH3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position External Pilot, External Drain Nitrile 240/60 - 220/50 VAC DIN with Plug Omit - High Watt High Pressure, AC Only 207 Bar (3000 psi) Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004B2NYC4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B2VJW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position External Pilot, External Drain Fluorocarbon 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B2VJW3F NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position External Pilot, External Drain Fluorocarbon 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Stroke Adjust A and B end
D61VW004B2VKG5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position External Pilot, External Drain Fluorocarbon 12 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004B2VYW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position External Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B4NJC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, Internal Drain Nitrile 24 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B4NYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B4NYG1C NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug(Mini) Single Solenoid 5-pin with Lights
D61VW004B4NYG5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004B4NYP NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B4NYPF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN with Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B4NYWF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B4VYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot, Internal Drain Fluorocarbon 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B5NYC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position External Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B5NYCF4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position External Pilot, Internal Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004B5VYCH NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position External Pilot, Internal Drain Fluorocarbon 120/60 - 110/50 VAC Leadwire Conduit Box Omit - High Watt High Pressure, AC Only 207 Bar (3000 psi) Omit - Standard Omit - No Options Omit - No Options
D61VW004B6NJW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Single solenoid, 2 position, spring offset. P to A and B to T in offset position Internal Pilot w/Check, Internal Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NDC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NJC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NJC4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NJCL NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC Leadwire Conduit Box 10 Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NJG3S NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Lights, Mini Manaplug, Pilot Choke Meter Out
D61VW004C1NJG5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C1NJG56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW004C1NJG563F NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (mini) w/Lights and Stroke Adjust at A and B Ends
D61VW004C1NJP NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NJP3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C1NJP4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NJP45 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C1NJP5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C1NJW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NJW1R NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Stroke Adjust A and B End with Pilot Choke Meter In
D61VW004C1NJW3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C1NJW3F NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Stroke Adjust A and B end
D61VW004C1NJW4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NJW43A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C1NJWL NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN w/o Plug 10 Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NJWP NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Extended with Boot Omit - No Options Omit - No Options
D61VW004C1NKC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 12 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NKC4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 12 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NTCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 240/60 - 220/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NTPF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 240/60 - 220/50 VAC DIN with Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NTW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 240/60 - 220/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NTWF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 240/60 - 220/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NYC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NYCF3F NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Stroke Adjust A and B end
D61VW004C1NYCF3K NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter out w/ Stroke Adjust A and B end
D61VW004C1NYCF4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NYCF43A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C1NYET NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Explosion Proof Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC None Omit - No Options Omit - No Options
D61VW004C1NYG3S NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Lights, Mini Manaplug, Pilot Choke Meter Out
D61VW004C1NYG45 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C1NYG56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW004C1NYGF3G NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out with Lights
D61VW004C1NYGF3W NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (mini) Double Solenoid 5-Pin w/Lights and Stroke Adjustment A and B Ends
D61VW004C1NYGF43G NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out with Lights
D61VW004C1NYGF45 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C1NYGF453A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights, Pilot Choke Meter Out
D61VW004C1NYGF456 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW004C1NYGF5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C1NYGF56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW004C1NYP NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NYPF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN with Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NYPF3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN with Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C1NYPF3G NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN with Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out with Lights
D61VW004C1NYPF5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN with Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C1NYW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NYW4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NYWF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NYWF3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C1NYWF4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1NYWF43A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C1NYWH3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt High Pressure, AC Only 207 Bar (3000 psi) Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C1VJG5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C1VJP5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C1VJW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1VJW4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1VYC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1VYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1VYEU NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC Explosion Proof Explosion Proof, UL/CSA Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1VYGF3S NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Lights, Mini Manaplug, Pilot Choke Meter Out
D61VW004C1VYGF456 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW004C1VYGF56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW004C1VYGZ56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Rectified Coil Manaplug (Mini) with Lights
D61VW004C1VYPF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC DIN with Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1VYW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1VYWF3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C1VYWF4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C1VYWF43A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C2NJG45 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C2NJG56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW004C2NJW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C2NKP NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 12 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C2NTW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 240/60 - 220/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C2NYC4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C2NYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C2NYG3S NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Lights, Mini Manaplug, Pilot Choke Meter Out
D61VW004C2NYG45 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C2NYG56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW004C2NYGF3S NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Lights, Mini Manaplug, Pilot Choke Meter Out
D61VW004C2NYGF5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C2NYGF56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW004C2NYPF3G NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN with Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out with Lights
D61VW004C2NYW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C2NYW4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C2NYWF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C2NYWF4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Nitrile 120/60 - 110/50 VAC DIN w/o Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C2VJP NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Fluorocarbon 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C2VJPL520 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Fluorocarbon 24 VDC DIN with Plug 10 Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Fast Response w/ Lights
D61VW004C2VYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered External Pilot, External Drain Fluorocarbon 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C3NYCF NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot w/Check, External Drain Nitrile 120/60 - 110/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C3NYGF5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot w/Check, External Drain Nitrile 120/60 - 110/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C4NDP NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 120 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C4NJC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C4NJC3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C4NJDJ5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Metric Plug (m12x1), Desina Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Diode Surge Suppresor Signal Lights
D61VW004C4NJEU NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Explosion Proof Explosion Proof, UL/CSA Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C4NJG3S NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Lights, Mini Manaplug, Pilot Choke Meter Out
D61VW004C4NJG3W NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (mini) Double Solenoid 5-Pin w/Lights and Stroke Adjustment A and B Ends
D61VW004C4NJG43G NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out with Lights
D61VW004C4NJG45 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C4NJG456 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW004C4NJG5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C4NJG56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (Mini) with Lights
D61VW004C4NJG563B NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug (mini) w/Lights and Pilot Choke Meter-in
D61VW004C4NJG7B NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Manaplug - Brad Harrison (12x1) Micro with Lights
D61VW004C4NJGJ3G NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Diode Surge Suppresor Pilot Choke Meter Out with Lights
D61VW004C4NJGJ3Y NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Diode Surge Suppresor Manaplug (micro) w/ Lights and Pilot Choke Meter-out
D61VW004C4NJGJ43Y NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Diode Surge Suppresor Manaplug (micro) w/ Lights and Pilot Choke Meter-out
D61VW004C4NJGJ5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Diode Surge Suppresor Signal Lights
D61VW004C4NJGJ56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Diode Surge Suppresor Manaplug (Mini) with Lights
D61VW004C4NJGL5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box 10 Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C4NJGLJ56 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box 10 Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Diode Surge Suppresor Manaplug (Mini) with Lights
D61VW004C4NJGLJ7Y NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box 10 Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Diode Surge Suppresor M12x1 Manaplug (4-pin), speicla iring and Lights
D61VW004C4NJGP5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC Plug-In Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Extended with Boot Omit - No Options Signal Lights
D61VW004C4NJP NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C4NJP3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C4NJP3F NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Stroke Adjust A and B end
D61VW004C4NJP4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C4NJP43G NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out with Lights
D61VW004C4NJP45 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C4NJP5 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Signal Lights
D61VW004C4NJPL NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN with Plug 10 Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C4NJPL1P NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN with Plug 10 Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Painted Body
D61VW004C4NJW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C4NJW3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C4NJW3E NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Stroke Adjust A end
D61VW004C4NJW3F NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Stroke Adjust A and B end
D61VW004C4NJW4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C4NJW43A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C4NJWL NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN w/o Plug 10 Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C4NJWT3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 24 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC None Omit - No Options Pilot Choke Meter Out
D61VW004C4NKC NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 12 VDC Leadwire Conduit Box Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C4NKP3G NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 12 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out with Lights
D61VW004C4NKP4 NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot CSA Approved 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 12 VDC DIN with Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C4NKPF3G NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 12 VDC DIN with Plug Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out with Lights
D61VW004C4NKW NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 12 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C4NKW3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 12 VDC DIN w/o Plug Omit - High Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C4NTCF3A NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 240/60 - 220/50 VAC Leadwire Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Pilot Choke Meter Out
D61VW004C4NTED NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 240/60 - 220/50 VAC Explosion Proof Explosion Proof, EEXD ATEX Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Omit - No Options
D61VW004C4NTGF3S NFPA D08, CETOP8, DIN NG25, Low Flow, D03 Pilot Omit - Standard Valve 4-way, 3 position; P Port Blocked Double solenoid, 3 position, spring centered Internal Pilot, Internal Drain Nitrile 240/60 - 220/50 VAC Plug-In Conduit Box Low Watt Omit - Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC Omit - Standard Omit - No Options Lights, Mini Manaplug, Pilot Choke Meter Out