Part
|
Size
|
Certificates
|
Spool Code
|
Spool Position
|
Pilot Connection
(Inlet/Drain)
|
Seal Material
|
Voltage
|
Connection
|
Solenoid Option
|
Tube
|
Override
|
Electrical Option
|
Options
|
D61VW009E6NYWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P to T; A & B Blocked; Open Crossover
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot w/Check, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW009E6VKG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P to T; A & B Blocked; Open Crossover
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot w/Check, Internal Drain
|
Fluorocarbon
|
12
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW009K1NJC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P to T; A & B Blocked; Open Crossover
|
Single
solenoid, 2 position, spring centered. P to A and B to T when energized
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW009K1NJCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P to T; A & B Blocked; Open Crossover
|
Single
solenoid, 2 position, spring centered. P to A and B to T when energized
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW009K1NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P to T; A & B Blocked; Open Crossover
|
Single
solenoid, 2 position, spring centered. P to A and B to T when energized
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW009K5NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P to T; A & B Blocked; Open Crossover
|
Single
solenoid, 2 position, spring centered. P to A and B to T when energized
|
External
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW009K6NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P to T; A & B Blocked; Open Crossover
|
Single
solenoid, 2 position, spring centered. P to A and B to T when energized
|
Internal
Pilot w/Check, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW011B1NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011B1NYCH
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011B1NYW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011B4NJG56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW011B4NJP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011B4NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C1NDC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C1NJDLJ5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
Metric
Plug (m12x1), Desina
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Diode
Surge Suppresor
|
Signal
Lights
|
D61VW011C1NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C1NKC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
12
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C1NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C1NYCF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW011C1NYCF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C1NYGF456
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW011C1NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW011C1NYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW011C1NYP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW011C1NYW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C1NYWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C1VYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW011C1VYW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C1VYWF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C2VYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW011C2VYW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C4NJDLJ5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
Metric
Plug (m12x1), Desina
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Diode
Surge Suppresor
|
Signal
Lights
|
D61VW011C4NJG456
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW011C4NJG56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW011C4NJGLJ7Y
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
Plug-In
Conduit Box
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Diode
Surge Suppresor
|
M12x1
Manaplug (4-pin), speicla iring and Lights
|
D61VW011C4NJP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C4NJP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW011C4NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C4NJW3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW011C4NJW3F
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Stroke
Adjust A and B end
|
D61VW011C4NJWL
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C4NYC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C4NYC3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW011C4NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C4NYCF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C4NYG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW011C4NYG56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW011C4NYGF3S
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Lights,
Mini Manaplug, Pilot Choke Meter Out
|
D61VW011C4NYGF456
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW011C4NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW011C4NYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW011C4NYGF7B
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
- Brad Harrison (12x1) Micro with Lights
|
D61VW011C4NYGH56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
High
Pressure, AC Only 207 Bar (3000 psi)
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW011C4NYP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW011C4NYW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C4NYWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C4NYWF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW011C4VJDJ5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
Metric
Plug (m12x1), Desina
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Diode
Surge Suppresor
|
Signal
Lights
|
D61VW011C4VJGJ56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Diode
Surge Suppresor
|
Manaplug
(Mini) with Lights
|
D61VW011C4VJGLJ56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
Plug-In
Conduit Box
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Diode
Surge Suppresor
|
Manaplug
(Mini) with Lights
|
D61VW011C4VJGLJ7Y
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
Plug-In
Conduit Box
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Diode
Surge Suppresor
|
M12x1
Manaplug (4-pin), speicla iring and Lights
|
D61VW011C4VJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C4VYC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C4VYCF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW011C4VYG3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW011C4VYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW011C4VYWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011C4VYWF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW011C6NYG56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot w/Check, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW011E4NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Single
solenoid, 2 position, spring centered. P to B and A to T when energized
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW011F4NYG56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Single
solenoid, 2 position, spring offset, energized to center. Spacer on A side. P
to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW011H4NJP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011H6NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Single
solenoid, 2 position, spring offset. P to B and A to T in offset position
|
Internal
Pilot w/Check, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW011K4VJGLJ7Y
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P port Blocked, Metered
|
Single
solenoid, 2 position, spring centered. P to A and B to T when energized
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
Plug-In
Conduit Box
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Diode
Surge Suppresor
|
M12x1
Manaplug (4-pin), speicla iring and Lights
|
D61VW012B1NJET
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
Explosion
Proof
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
None
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012B1NJG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW012B1NYCF3D
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Stroke
Adjust B end
|
D61VW012B1NYG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW012B1NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW012B2NJC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
External
Pilot, External Drain
|
Nitrile
|
24
VDC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012B2NJG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
External
Pilot, External Drain
|
Nitrile
|
24
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW012B2NYCF3K
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
External
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter out w/ Stroke Adjust A and B end
|
D61VW012B2NYCF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
External
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012B2NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
External
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW012B4NJEE
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
Explosion
Proof
|
Explosion
Proof EEXME ATEX
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012B4NYC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012B4NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012B4NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW012B4VYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring offset. P to A and B to T in offset position
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW012C1NJG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW012C1NJP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012C1NKWL
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
12
VDC
|
DIN
w/o Plug
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012C1NYC
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012C1NYW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012C2NJP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012C2NJP3R
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out and Pilot Pressure Reducer
|
D61VW012C2NTPF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, External Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
DIN
with Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012C2NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012C3NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot w/Check, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012C4VYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012C4VYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW012D1NJET
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
Explosion
Proof
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
None
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012D4NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW012D4NYPZ
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Rectified
Coil
|
Omit
- No Options
|
D61VW012D4NYPZ3C
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Double
solenoid, 2 position, detent
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Rectified
Coil
|
Pilot
Pressure Reducer
|
D61VW012K4VYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; All Ports Open, Metered
|
Single
solenoid, 2 position, spring centered. P to A and B to T when energized
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW015C1NJP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW015C1NJP3F
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Stroke
Adjust A and B end
|
D61VW015C1NTP3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
240/60
- 220/50 VAC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW015C1NYWF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW015C1VYGF3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW015C1VYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW015C4NJP
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW015C4NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW015C4NYC4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW015C4NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW015C4VYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW015C4VYW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW015C5NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW015C5VYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW015C5VYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; B to T and A and P Ports Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW016C1VYWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P to B and A and T Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW016C4NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P to B and A and T Blocked
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW016C5NYWF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P to B and A and T Blocked
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW016K1NUW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position; P to B and A and T Blocked
|
Single
solenoid, 2 position, spring centered. P to A and B to T when energized
|
Internal
Pilot, External Drain
|
Nitrile
|
98
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW021C1NJW3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position: Closed Center Regen P to A side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW021C1NYCF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position: Closed Center Regen P to A side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW021C4NJCL
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position: Closed Center Regen P to A side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
Leadwire
Conduit Box
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW021C4NYGF5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position: Closed Center Regen P to A side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW021C4NYWF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way,
3 position: Closed Center Regen P to A side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
DIN
w/o Plug
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW021C4VJP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position: Closed Center Regen P to A side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
DIN
with Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW021C4VYG3G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position: Closed Center Regen P to A side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW021C4VYG5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position: Closed Center Regen P to A side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW021C5NJW
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way,
3 position: Closed Center Regen P to A side
|
Double
solenoid, 3 position, spring centered
|
External
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
w/o Plug
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW022C1NYCF4
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way
3 position, Closed Center Regen P to B Side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW022C1NYGF56
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way
3 position, Closed Center Regen P to B Side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, External Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Manaplug
(Mini) with Lights
|
D61VW022C4NJPLP5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way
3 position, Closed Center Regen P to B Side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
24
VDC
|
DIN
with Plug
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Extended
with Boot
|
Omit
- No Options
|
Signal
Lights
|
D61VW022C4NYCF
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way
3 position, Closed Center Regen P to B Side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Omit
- No Options
|
D61VW022C4NYCF3A
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way
3 position, Closed Center Regen P to B Side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Leadwire
Conduit Box
|
Low
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out
|
D61VW022C4NYG43G
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way
3 position, Closed Center Regen P to B Side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Pilot
Choke Meter Out with Lights
|
D61VW022C4NYG45
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
CSA
Approved
|
4-way
3 position, Closed Center Regen P to B Side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Nitrile
|
120/60
- 110/50 VAC
|
Plug-In
Conduit Box
|
Omit
- High Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|
D61VW022C4VJPL5
|
NFPA
D08, CETOP8, DIN NG25, Low Flow, D03 Pilot
|
Omit
- Standard Valve
|
4-way
3 position, Closed Center Regen P to B Side
|
Double
solenoid, 3 position, spring centered
|
Internal
Pilot, Internal Drain
|
Fluorocarbon
|
24
VDC
|
DIN
with Plug
|
10
Watt
|
Omit
- Standard Pressure 103.5 Bar (1500 PSI) AC; 207 Bar (3000 PSI) DC
|
Omit
- Standard
|
Omit
- No Options
|
Signal
Lights
|