Parker pilot operated pressure relief valves series R5V and R5V*P2 provide an outstanding constant pressure behaviour.

The SAE flanges allow to mount the valves directly on the flanges of pumps or actuators to achieve a very compact design.

Part Actuation Nominal Size Flange Body Type Pressure Range (bar) Adjustment Type Drain Option Switching Options Input Voltage Material - Seals
R5V06-69312P2G0RA1 Proportional SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line internal na 12 (DC) NBR
R5V06-6933209G0QA1 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V06-6933209G0QA1152 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V06-69332A1152 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal na na NBR
R5V06-6951209G0QA1 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V06-6951209G0QA1008 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V06-6951209G0QA1152 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V06-6951211G0QA1 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line internal Solenoid activated unpress. Circulation 24 (DC) NBR
R5V06-69512A1 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line internal na na NBR
R5V06-69512A1152 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line internal na na NBR
R5V06-69512P2G0RA1 Proportional SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line internal na 12 (DC) NBR
R5V06-6951611G0QA1 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line external from Y1-port Solenoid activated unpress. Circulation 24 (DC) NBR
R5V06-6953209G0QA1008 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V06-6953209G0QA1152 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V06-6953209G0QA5152 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) FPM
R5V06-6953211G0QA1 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line internal Solenoid activated unpress. Circulation 24 (DC) NBR
R5V06-69536A1 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line external from Y1-port na na NBR
R5V06-69536A1152 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line external from Y1-port na na NBR
R5V06-6954611G0QA1 Manually SAE 3/4 SAE62 3-port, Y1, X1, M = G 1/4 350 Cylinder lock Drain line external from Y1-port Solenoid activated unpress. Circulation 24 (DC) NBR
R5V08-5711209G0QA1 Manually SAE 1 SAE61 2-port, Y1 = G 1/4 105 Hand knob Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5731209W30A5 Manually SAE 1 SAE61 2-port, Y1 = G 1/4 210 Hand knob Drain line internal Solenoid not activated unpress. Circulation 110/120 (AC), 50/60 (Hz) FPM
R5V08-5733209G0QA1 Manually SAE 1 SAE61 2-port, Y1 = G 1/4 210 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5733209W31A1008 Manually SAE 1 SAE61 2-port, Y1 = G 1/4 210 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 230/240 (AC), 50/60 (Hz) NBR
R5V08-5733611G0QA1 Manually SAE 1 SAE61 2-port, Y1 = G 1/4 210 Acorn nut with lead seal Drain line external from Y1-port Solenoid activated unpress. Circulation 24 (DC) NBR
R5V08-57512P2G0RA1 Proportional SAE 1 SAE61 2-port, Y1 = G 1/4 350 Hand knob Drain line internal na 12 (DC) NBR
R5V08-57516P2G0RA1 Proportional SAE 1 SAE61 2-port, Y1 = G 1/4 350 Hand knob Drain line external from Y1-port na 12 (DC) NBR
R5V08-57516P2G0RA5 Proportional SAE 1 SAE61 2-port, Y1 = G 1/4 350 Hand knob Drain line external from Y1-port na 12 (DC) FPM
R5V08-57532A1 Manually SAE 1 SAE61 2-port, Y1 = G 1/4 350 Acorn nut with lead seal Drain line internal na na NBR
R5V08-5911209W30A1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 Hand knob Drain line internal Solenoid not activated unpress. Circulation 110/120 (AC), 50/60 (Hz) NBR
R5V08-5911209W31A1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 Hand knob Drain line internal Solenoid not activated unpress. Circulation 230/240 (AC), 50/60 (Hz) NBR
R5V08-5913209G0QA1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5913209G0QA1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5913211G0QA1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 Acorn nut with lead seal Drain line internal Solenoid activated unpress. Circulation 24 (DC) NBR
R5V08-5913211G0QA1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 Acorn nut with lead seal Drain line internal Solenoid activated unpress. Circulation 24 (DC) NBR
R5V08-59136A1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 105 Acorn nut with lead seal Drain line external from Y1-port na na NBR
R5V08-5931209G0QA1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5931209G0QA5 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line internal Solenoid not activated unpress. Circulation 24 (DC) FPM
R5V08-5931209GARA1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line internal Solenoid not activated unpress. Circulation 98 (DC) NBR
R5V08-5931211G0QA1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line internal Solenoid activated unpress. Circulation 24 (DC) NBR
R5V08-59312A1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line internal na na NBR
R5V08-59312P2G0RA1 Proportional SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line internal na 12 (DC) NBR
R5V08-5931609G0QA1008 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line external from Y1-port Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5931611G0QA1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line external from Y1-port Solenoid activated unpress. Circulation 24 (DC) NBR
R5V08-5931611W31A1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line external from Y1-port Solenoid activated unpress. Circulation 230/240 (AC), 50/60 (Hz) NBR
R5V08-59316A1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line external from Y1-port na na NBR
R5V08-59316P2G0RA1 Proportional SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line external from Y1-port na 12 (DC) NBR
R5V08-5933209G0QA1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5933209G0QA5008 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) FPM
R5V08-5933209G0QA5152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) FPM
R5V08-5933209W30A1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 110/120 (AC), 50/60 (Hz) NBR
R5V08-5933211G0QA1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal Solenoid activated unpress. Circulation 24 (DC) NBR
R5V08-59332P2G0RA1 Proportional SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal na 12 (DC) NBR
R5V08-5933609G0QA1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5933609G0QA1008 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5933609G0QA1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5933609G0RA1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. Circulation 12 (DC) NBR
R5V08-59336A1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line external from Y1-port na na NBR
R5V08-59336P2G0RA1 Proportional SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line external from Y1-port na 12 (DC) NBR
R5V08-59336P2G0RA1152 Proportional SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line external from Y1-port na 12 (DC) NBR
R5V08-5934209G0QA1008 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 210 Cylinder lock Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5951209G0QA1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5951211G0QA1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line internal Solenoid activated unpress. Circulation 24 (DC) NBR
R5V08-5951211G0QA1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line internal Solenoid activated unpress. Circulation 24 (DC) NBR
R5V08-59512A1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line internal na na NBR
R5V08-59512P2G0RA1 Proportional SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line internal na 12 (DC) NBR
R5V08-59512P2G0RA1152 Proportional SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line internal na 12 (DC) NBR
R5V08-5951609G0QA1008 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line external from Y1-port Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5951609W30A1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line external from Y1-port Solenoid not activated unpress. Circulation 110/120 (AC), 50/60 (Hz) NBR
R5V08-59516A5 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Hand knob Drain line external from Y1-port na na FPM
R5V08-5953209G0QA5 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) FPM
R5V08-5953209G0QA5152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) FPM
R5V08-5953209G0RA1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 12 (DC) NBR
R5V08-5953209W31A1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 230/240 (AC), 50/60 (Hz) NBR
R5V08-59532A5 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line internal na na FPM
R5V08-59532A525152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line internal na na FPM
R5V08-5953609G0QA1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-5953609G0RA1152 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line external from Y1-port Solenoid not activated unpress. Circulation 12 (DC) NBR
R5V08-59536A1 Manually SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line external from Y1-port na na NBR
R5V08-59536P2G0RA5 Proportional SAE 1 SAE61 3-port, Y1, X1, M = G 1/4 350 Acorn nut with lead seal Drain line external from Y1-port na 12 (DC) FPM
R5V08-69116P2G0RA1 Proportional SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 105 Hand knob Drain line external from Y1-port na 12 (DC) NBR
R5V08-6913209G0QA1 Manually SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 105 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-6931209W30A1008 Manually SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line internal Solenoid not activated unpress. Circulation 110/120 (AC), 50/60 (Hz) NBR
R5V08-6931211W31A1 Manually SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line internal Solenoid activated unpress. Circulation 230/240 (AC), 50/60 (Hz) NBR
R5V08-69312A1 Manually SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line internal na na NBR
R5V08-69312A5 Manually SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line internal na na FPM
R5V08-6931609G0QA1 Manually SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 Hand knob Drain line external from Y1-port Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-6933209G0QA1008 Manually SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-6933209G0QA1152 Manually SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) NBR
R5V08-6933209G0QA5152 Manually SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal Solenoid not activated unpress. Circulation 24 (DC) FPM
R5V08-6933211G0QA1152 Manually SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal Solenoid activated unpress. Circulation 24 (DC) NBR
R5V08-69332A1152 Manually SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal na na NBR
R5V08-69332A5152 Manually SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 Acorn nut with lead seal Drain line internal na na FPM
R5V08-69342A5152 Manually SAE 1 SAE62 3-port, Y1, X1, M = G 1/4 210 Cylinder lock Drain line internal na na FPM