IFM Capacitivetive sensors | 
                        |
|---|---|
| Category: | Sensor | 
| Master Model: | N/A | 
| Drawing No.: | N/A | 
| Quantity: | - + EA | 
| Price: | Inquiry | 
| Payment: | T/T, PayPal, More | 
| Shipping Cost: | To be confirmed | 
| Inquiry Add to Wishlist | |
	High noise immunity
Sensing range adjustable by means of potentiometer or teach button
Plastic or metal housings for different applications
Accessories for mounting on tanks or sight glasses 
| 
				 Product  | 
			
				 Sensing range  | 
			
				 Output function  | 
			
				 Output  | 
			
				 Dimensions  | 
			
				 Connection  | 
		
| 
				 KI0205  | 
			
				 3...15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 / L = 125 mm  | 
			
				 terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm  | 
		
| 
				 KI0202  | 
			
				 3...15 mm non-flush mountable  | 
			
				 normally open  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KI0203  | 
			
				 3...15 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KI0054  | 
			
				 5...40 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 / L = 90 mm  | 
			
				 1/2" Connector  | 
		
| 
				 KF5001  | 
			
				 1...6 mm flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M12 x 1 / L = 60 mm  | 
			
				 M12 Connector  | 
		
| 
				 KI0206  | 
			
				 3...15 mm non-flush mountable  | 
			
				 normally open  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 mm  | 
			
				 0.1 m PVC-Cable; 1/2" Connector  | 
		
| 
				 KI6000  | 
			
				 0.5...40 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 92 mm  | 
			
				 M12 Connector  | 
		
| 
				 KI0207  | 
			
				 3...15 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 mm  | 
			
				 0.1 m PVC-Cable; 1/2" Connector  | 
		
| 
				 KI5082  | 
			
				 20 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP/NPN  | 
			
				 M30 x 1.5 / L = 90 mm  | 
			
				 M12 Connector  | 
		
| 
				 KI5207  | 
			
				 3...15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KI5083  | 
			
				 20 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 90 mm  | 
			
				 M12 Connector  | 
		
| 
				 KI5209  | 
			
				 3...15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 0.1 m PUR-Cable; M12 Connector  | 
		
| 
				 KF5002  | 
			
				 3...12 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M12 x 1 / L = 61 mm  | 
			
				 M12 Connector  | 
		
| 
				 KI5085  | 
			
				 8 mm flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 90 mm  | 
			
				 M12 Connector  | 
		
| 
				 KG6000  | 
			
				 0.5...30 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 M12 Connector  | 
		
| 
				 KQ6005  | 
			
				 12 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 20 x 14 x 48 mm  | 
			
				 0.1 m PVC-Cable; M12 Connector  | 
		
| 
				 KD0024  | 
			
				 60 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 
					   | 
			
				 terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm  | 
		
| 
				 KG5065  | 
			
				 12 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP/NPN  | 
			
				 M18 x 1 / L = 87 mm  | 
			
				 M12 Connector  | 
		
| 
				 KG3500  | 
			
				 8 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 M18 x 1 mm  | 
			
				 1/2" Connector  | 
		
| 
				 KI5208  | 
			
				 3...15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC NPN  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KG0009  | 
			
				 8 mm non-flush mountable  | 
			
				 normally open  | 
			
				 AC/DC  | 
			
				 M18 x 1 / L = 84 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KG0008  | 
			
				 8 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 M18 x 1 / L = 110 mm  | 
			
				 terminals: ...2,5 mm²; Cable sheath: Ø 4,5...10 mm  | 
		
| 
				 KG5047  | 
			
				 8 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP/NPN  | 
			
				 M18 x 1 / L = 84 mm  | 
			
				 2 m PUR / PVC-Cable  | 
		
| 
				 KQ6004  | 
			
				 12 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 20 x 14 x 48 mm  | 
			
				 0.04 m PVC-Cable; M8 Connector  | 
		
| 
				 KG0010  | 
			
				 8 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 AC/DC  | 
			
				 M18 x 1 / L = 84 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KI0024  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 / L = 125 mm  | 
			
				 terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm  | 
		
| 
				 KI5052  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 143 mm  | 
			
				 M12 Connector  | 
		
| 
				 KI5023  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 125 mm  | 
			
				 terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm  | 
		
| 
				 KG5066  | 
			
				 12 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 87 mm  | 
			
				 M12 Connector  | 
		
| 
				 KT5002  | 
			
				 
					   | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 100 / L = 11 mm  | 
			
				 0.3 m PUR-Cable; M8 Connector  | 
		
| 
				 KG8500  | 
			
				 2.5...8 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP/NPN  | 
			
				 M18 x 1 mm  | 
			
				 M12 Connector  | 
		
| 
				 KD5018  | 
			
				 60 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 105 x 80 x 40 mm  | 
			
				 terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm  | 
		
| 
				 KT5001  | 
			
				 
					   | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 100 / L = 11 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KG0016  | 
			
				 4...24 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 M18 x 1 / L = 87 mm  | 
			
				 1/2" Connector  | 
		
| 
				 KI5087  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 90 mm  | 
			
				 M12 Connector  | 
		
| 
				 KI5031  | 
			
				 15 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC NAMUR  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 6 m PVC-Cable  | 
		
| 
				 KB5004  | 
			
				 3...20 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 34 / L = 81 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KQ6001  | 
			
				 12 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP/NPN  | 
			
				 20 x 14 x 48 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KI505A  | 
			
				 15 mm non-flush mountable  | 
			
				 complementary  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 125 mm  | 
			
				 terminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm  | 
		
| 
				 KT5006  | 
			
				 
					   | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 100 / L = 11 mm  | 
			
				 0.3 m PUR-Cable; M8 Connector  | 
		
| 
				 KD3500  | 
			
				 60 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 
					   | 
			
				 7/8" Connector  | 
		
| 
				 KG5043  | 
			
				 8 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 84 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KI5084  | 
			
				 8 mm flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP/NPN  | 
			
				 M30 x 1.5 / L = 90 mm  | 
			
				 M12 Connector  | 
		
| 
				 KI5030  | 
			
				 15 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC NAMUR  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KN5121  | 
			
				 
					   | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 116 mm  | 
			
				 2 m; M12 Connector  | 
		
| 
				 KQ6002  | 
			
				 12 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 20 x 14 x 48 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KF5013  | 
			
				 1...6 mm flush mountable  | 
			
				 normally open  | 
			
				 DC NPN  | 
			
				 M12 x 1 / L = 60 mm  | 
			
				 M12 Connector  | 
		
| 
				 KT5007  | 
			
				 
					   | 
			
				 normally open  | 
			
				 DC NPN  | 
			
				 Ø 96.9 / L = 11 mm  | 
			
				 0.3 m PUR-Cable; M8 Connector  | 
		
| 
				 KQ6003  | 
			
				 12 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP/NPN  | 
			
				 20 x 14 x 48 mm  | 
			
				 0.04 m PVC-Cable; M8 Connector  | 
		
| 
				 KG5057  | 
			
				 8 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 93.8 mm  | 
			
				 M12 Connector  | 
		
| 
				 KG5067  | 
			
				 8 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP/NPN  | 
			
				 M18 x 1 / L = 77 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KI5086  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP/NPN  | 
			
				 M30 x 1.5 / L = 90 mm  | 
			
				 M12 Connector  | 
		
| 
				 KG5069  | 
			
				 8 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 77 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KB0029  | 
			
				 3...20 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 AC/DC  | 
			
				 Ø 34 / L = 81 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KI5002  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KG5045  | 
			
				 8 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC NPN  | 
			
				 M18 x 1 / L = 84 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KD5039  | 
			
				 60 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 105 x 80 x 40 mm  | 
			
				 M12 Connector  | 
		
| 
				 KG5040  | 
			
				 2.5...8 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP/NPN  | 
			
				 M18 x 1 / L = 110 mm  | 
			
				 terminals: ...2,5 mm²; Cable sheath: Ø 4,5...10 mm  | 
		
| 
				 KD5044  | 
			
				 60 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 105 x 80 x 40 mm  | 
			
				 M12 Connector  | 
		
| 
				 KI8505  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 mm  | 
			
				 M12 Connector  | 
		
| 
				 KG5071  | 
			
				 8 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 87 mm  | 
			
				 M12 Connector  | 
		
| 
				 KT5005  | 
			
				 
					   | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 100 / L = 11 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KG5046  | 
			
				 8 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC NPN  | 
			
				 M18 x 1 / L = 84 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KT6301  | 
			
				 
					   | 
			
				 normally open / closed  | 
			
				 DC PNP/NPN  | 
			
				 
					   | 
			
				 0.3 m PUR-Cable; M12 Connector  | 
		
| 
				 KD0012  | 
			
				 60 mm non-flush mountable  | 
			
				 normally open  | 
			
				 AC/DC  | 
			
				 120 x 80 x 30 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KT5020  | 
			
				 
					   | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 96.9 / L = 11 mm  | 
			
				 0.3 m PUR-Cable; M12 Connector  | 
		
| 
				 KG6001  | 
			
				 0.5...30 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KB5062  | 
			
				 20 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 34 / L = 93 mm  | 
			
				 M12 Connector  | 
		
| 
				 KD5022  | 
			
				 60 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 120 x 80 x 30 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KD3501  | 
			
				 60 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 105 x 80 x 40 mm  | 
			
				 M12 Connector  | 
		
| 
				 KI503A  | 
			
				 15 mm non-flush mountable  | 
			
				 complementary  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 150 mm  | 
			
				 terminals: 0,34...1,5 mm²; Cable sheath: Ø 5...9 mm  | 
		
| 
				 KI5038  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 92 mm  | 
			
				 valve plug type A DIN Connector  | 
		
| 
				 KT6300  | 
			
				 
					   | 
			
				 normally open / closed  | 
			
				 DC PNP/NPN  | 
			
				 
					   | 
			
				 2 m PUR-Cable  | 
		
| 
				 KT5102  | 
			
				 
					   | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 29 / L = 31 mm  | 
			
				 0.3 m PUR-Cable; M12 Connector  | 
		
| 
				 KT6101  | 
			
				 
					   | 
			
				 normally open / closed  | 
			
				 DC PNP/NPN  | 
			
				 
					   | 
			
				 0.3 m PUR-Cable; M12 Connector  | 
		
| 
				 KG5309  | 
			
				 0.5...30 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 M12 Connector  | 
		
| 
				 KG5304  | 
			
				 0.5...9 mm quasi flush  | 
			
				 normally closed  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KG5305  | 
			
				 0.5...9 mm quasi flush  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KG5079  | 
			
				 8 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC NAMUR  | 
			
				 M18 x 1 / L = 84 mm  | 
			
				 6 m PVC-Cable  | 
		
| 
				 KI0058  | 
			
				 20 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 / L = 90 mm  | 
			
				 1/2" Connector  | 
		
| 
				 KB0040  | 
			
				 3...20 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 AC/DC  | 
			
				 Ø 34 / L = 81 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KI5210  | 
			
				 3...15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC NPN  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 0.1 m PUR-Cable; M12 Connector  | 
		
| 
				 KT6100  | 
			
				 
					   | 
			
				 normally open / closed  | 
			
				 DC PNP/NPN  | 
			
				 
					   | 
			
				 2 m PUR-Cable  | 
		
| 
				 KI5311  | 
			
				 0.5...24 mm quasi flush  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 92 mm  | 
			
				 M12 Connector  | 
		
| 
				 KG8502  | 
			
				 2.5...8 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M18 x 1 mm  | 
			
				 M12 Connector  | 
		
| 
				 KG5041  | 
			
				 8 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 110 mm  | 
			
				 terminals: ...2,5 mm²; Cable sheath: Ø 4,5...10 mm  | 
		
| 
				 KI5307  | 
			
				 0.5...40 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 92 mm  | 
			
				 M12 Connector  | 
		
| 
				 KI0040  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 / L = 92 mm  | 
			
				 valve plug type A DIN Connector  | 
		
| 
				 KG5044  | 
			
				 8 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 84 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KI0016  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KT5009  | 
			
				 
					   | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 100 / L = 11 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KI5001  | 
			
				 15 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KQ6006  | 
			
				 12 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC NPN  | 
			
				 20 x 14 x 48 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KI5309  | 
			
				 0.5...40 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 92 mm  | 
			
				 M12 Connector  | 
		
| 
				 KT5013  | 
			
				 
					   | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 96.9 / L = 11 mm  | 
			
				 0.3 m PUR-Cable; M8 Connector  | 
		
| 
				 KQ5101  | 
			
				 12 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 20 x 7 x 48 mm  | 
			
				 0.1 m PUR-Cable; M12 Connector  | 
		
| 
				 KG5311  | 
			
				 0.5...9 mm quasi flush  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 M12 Connector  | 
		
| 
				 KI5306  | 
			
				 0.5...40 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC NPN  | 
			
				 M30 x 1.5 / L = 92 mm  | 
			
				 M12 Connector  | 
		
| 
				 KI6003  | 
			
				 0.5...40 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC NPN  | 
			
				 M30 x 1.5 / L = 92 mm  | 
			
				 10 m PUR-Cable  | 
		
| 
				 KI5019  | 
			
				 15 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC NPN  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KD001A  | 
			
				 60 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 105 x 80 x 42 mm  | 
			
				 terminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm  | 
		
| 
				 KI5310  | 
			
				 0.5...24 mm quasi flush  | 
			
				 normally closed  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 92 mm  | 
			
				 M12 Connector  | 
		
| 
				 KG5307  | 
			
				 0.5...30 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 M12 Connector  | 
		
| 
				 KF5014  | 
			
				 4 mm flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M12 x 1 / L = 69 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KI6001  | 
			
				 0.5...40 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 92 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KQ5100  | 
			
				 12 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 20 x 7 x 48 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KI001A  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 / L = 125 mm  | 
			
				 terminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm  | 
		
| 
				 KT5010  | 
			
				 
					   | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 96.9 / L = 11 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KI5308  | 
			
				 0.5...40 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC NPN  | 
			
				 M30 x 1.5 / L = 92 mm  | 
			
				 M12 Connector  | 
		
| 
				 KD5019  | 
			
				 60 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC NPN  | 
			
				 105 x 80 x 40 mm  | 
			
				 terminals: ...2,5 mm²; Cable sheath: Ø 7...13 mm  | 
		
| 
				 KG5308  | 
			
				 0.5...30 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC NPN  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 M12 Connector  | 
		
| 
				 KQ5011  | 
			
				 8 mm  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 20 x 7 x 48 mm  | 
			
				 0.76 m PUR-Cable; MOLEX Connector  | 
		
| 
				 KG5303  | 
			
				 0.5...30 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KQ1001  | 
			
				 
					   | 
			
				 
					   | 
			
				 DC PNP/NPN  | 
			
				 250 x 28 x 16.7 mm  | 
			
				 0.1 m PUR-Cable; M12 Connector  | 
		
| 
				 KG5310  | 
			
				 0.5...9 mm quasi flush  | 
			
				 normally closed  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 M12 Connector  | 
		
| 
				 KG5300  | 
			
				 0.5...30 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC NPN  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KG5301  | 
			
				 0.5...30 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KG5302  | 
			
				 0.5...30 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC NPN  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KG5306  | 
			
				 0.5...30 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC NPN  | 
			
				 M18 x 1 / L = 92.5 mm  | 
			
				 M12 Connector  | 
		
| 
				 KQ1000  | 
			
				 
					   | 
			
				 
					   | 
			
				 DC PNP/NPN  | 
			
				 250 x 28 x 16.7 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KI000A  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 / L = 150 mm  | 
			
				 terminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm  | 
		
| 
				 KT5011  | 
			
				 
					   | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 96.9 / L = 11 mm  | 
			
				 0.3 m PUR-Cable; M8 Connector  | 
		
| 
				 KD501A  | 
			
				 60 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 105 x 80 x 42 mm  | 
			
				 terminals: 0,34...2,5 mm²; Cable sheath: Ø 5...9 mm  | 
		
| 
				 KX5001  | 
			
				 15 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC NAMUR  | 
			
				 M34 x 1.5 / L = 92 mm  | 
			
				 2 m PVC-Cable  | 
		
| 
				 KG5070  | 
			
				 8 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 M18 x 1 / L = 77 mm  | 
			
				 10 m PVC-Cable  | 
		
| 
				 KT5012  | 
			
				 
					   | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 96.9 / L = 11 mm  | 
			
				 2 m PUR-Cable  | 
		
| 
				 KX5002  | 
			
				 15 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC NAMUR  | 
			
				 M34 x 1.5 / L = 92 mm  | 
			
				 6 m PVC-Cable  | 
		
| 
				 KX5004  | 
			
				 15 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC NAMUR  | 
			
				 M34 x 1.5 / L = 92 mm  | 
			
				 20 m PVC-Cable  | 
		
| 
				 KI5003  | 
			
				 15 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 6 m PVC-Cable  | 
		
| 
				 KI5006  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 6 m PVC-Cable  | 
		
| 
				 KQ6016  | 
			
				 12 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC NPN  | 
			
				 20 x 14 x 48 mm  | 
			
				 2 m PVC-Cable; M12 Connector  | 
		
| 
				 KQ6010  | 
			
				 12 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 DC PNP  | 
			
				 20 x 14 x 48 mm  | 
			
				 0.04 m PVC-Cable; M8 Connector  | 
		
| 
				 KB0026  | 
			
				 3...20 mm non-flush mountable  | 
			
				 normally open  | 
			
				 AC/DC  | 
			
				 Ø 34 / L = 81 mm  | 
			
				 6 m PVC-Cable  | 
		
| 
				 KI3511  | 
			
				 3...15 mm non-flush mountable  | 
			
				 normally open / closed; (selectable)  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 mm  | 
			
				 1/2" Connector  | 
		
| 
				 KI0017  | 
			
				 15 mm non-flush mountable  | 
			
				 normally open  | 
			
				 AC/DC  | 
			
				 M30 x 1.5 / L = 81 mm  | 
			
				 6 m PVC-Cable  | 
		
| 
				 KB5014  | 
			
				 3...20 mm non-flush mountable  | 
			
				 normally open  | 
			
				 DC PNP  | 
			
				 Ø 34 / L = 81 mm  | 
			
				 6 m PVC-Cable  | 
		
| 
				 KQ5012  | 
			
				 4.7 mm non-flush mountable  | 
			
				 normally closed  | 
			
				 DC NPN  | 
			
				 20 x 7 x 48 mm  | 
			
				 0.4 m PUR-Cable; MOLEX Connector  |