Directional Control Valve - Series D1VW / D1VW*EE

Category: Valve
Master Model: N/A
Drawing No.: N/A
Quantity: - + EA
Price: Inquiry
Payment: T/T, PayPal, More
Shipping Cost: To be confirmed
Inquiry Add to Wishlist
                         
If you need a specific Directional Control Valve - Series D1VW / D1VW*EE firmware or series. Please call or email us your request.

  Guaranteed Fitment

  Specialist Team

  Response Rate High

  Quick & Hassle Free

The D1VW in NG06 (CETOP 03) is an on/off valve which provides high functional limits in combination with a very low, energy-saving pressure drop.

It is optionally available with soft shift option or as explosion proof version according to ATEX and IECEx.

Part

Spool Code

Spool Position

Input Voltage

Solenoid option

Seal Material

D1VW006CNTW

006

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW006CNUW

006

3 positions, spring offset in position 0, operated in position a or b

98 (DC)

Standard

NBR

D1VW006CNUWS3

006

3 positions, spring offset in position 0, operated in position a or b

98 (DC)

Soft shift

NBR

D1VW006CNYW

006

3 positions, spring offset in position 0, operated in position a or b

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW006CNYWT

006

3 positions, spring offset in position 0, operated in position a or b

110/120 (AC), 50/60 Hz

Without manual override

NBR

D1VW006CVJW

006

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Standard

FPM

D1VW006CVTW

006

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Standard

FPM

D1VW006ENGW

006

2 positions, spring offset in position 0, operated in position a

205 (DC)

Standard

NBR

D1VW006ENJW

006

2 positions, spring offset in position 0, operated in position a

24 (DC)

Standard

NBR

D1VW006ENJWS2

006

2 positions, spring offset in position 0, operated in position a

24 (DC)

Soft shift

NBR

D1VW006ENJWT

006

2 positions, spring offset in position 0, operated in position a

24 (DC)

Without manual override

NBR

D1VW006ENKW

006

2 positions, spring offset in position 0, operated in position a

12 (DC)

Standard

NBR

D1VW006ENPEE

006

2 positions, spring offset in position 0, operated in position a

110 (AC), 50 (Hz)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW006ENTW

006

2 positions, spring offset in position 0, operated in position a

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW006ENYW

006

2 positions, spring offset in position 0, operated in position a

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW006ENYWT

006

2 positions, spring offset in position 0, operated in position a

110/120 (AC), 50/60 Hz

Without manual override

NBR

D1VW006FNJEE

006

2 positions, operated in position 0, spring offset in position b

24 (DC)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW006FNJW

006

2 positions, operated in position 0, spring offset in position b

24 (DC)

Standard

NBR

D1VW006FNJW4N

006

2 positions, operated in position 0, spring offset in position b

24 (DC)

With lockable manual override

NBR

D1VW006FNJWT

006

2 positions, operated in position 0, spring offset in position b

24 (DC)

Without manual override

NBR

D1VW006FNKW

006

2 positions, operated in position 0, spring offset in position b

12 (DC)

Standard

NBR

D1VW006FNNEE

006

2 positions, operated in position 0, spring offset in position b

230 (AC), 50 (Hz)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW006FNTW

006

2 positions, operated in position 0, spring offset in position b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW006FNUW

006

2 positions, operated in position 0, spring offset in position b

98 (DC)

Standard

NBR

D1VW006FNYW

006

2 positions, operated in position 0, spring offset in position b

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW006FVJEE

006

2 positions, operated in position 0, spring offset in position b

24 (DC)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

FPM

D1VW006FVJW

006

2 positions, operated in position 0, spring offset in position b

24 (DC)

Standard

FPM

D1VW006KNGW

006

2 positions, spring offset in position 0, operated in position b

205 (DC)

Standard

NBR

D1VW006KNJEE

006

2 positions, spring offset in position 0, operated in position b

24 (DC)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW006KNJW

006

2 positions, spring offset in position 0, operated in position b

24 (DC)

Standard

NBR

D1VW006KNJW4N

006

2 positions, spring offset in position 0, operated in position b

24 (DC)

With lockable manual override

NBR

D1VW006KNJWS2

006

2 positions, spring offset in position 0, operated in position b

24 (DC)

Soft shift

NBR

D1VW006KNJWS3

006

2 positions, spring offset in position 0, operated in position b

24 (DC)

Soft shift

NBR

D1VW006KNJWT

006

2 positions, spring offset in position 0, operated in position b

24 (DC)

Without manual override

NBR

D1VW006KNKW

006

2 positions, spring offset in position 0, operated in position b

12 (DC)

Standard

NBR

D1VW006KNTW

006

2 positions, spring offset in position 0, operated in position b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW006KNUW

006

2 positions, spring offset in position 0, operated in position b

98 (DC)

Standard

NBR

D1VW006KNYW

006

2 positions, spring offset in position 0, operated in position b

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW006KNYWT

006

2 positions, spring offset in position 0, operated in position b

110/120 (AC), 50/60 Hz

Without manual override

NBR

D1VW006KVJW

006

2 positions, spring offset in position 0, operated in position b

24 (DC)

Standard

FPM

D1VW006KVTW

006

2 positions, spring offset in position 0, operated in position b

230/240 (AC), 50/60 Hz

Standard

FPM

D1VW006KVYW

006

2 positions, spring offset in position 0, operated in position b

110/120 (AC), 50/60 Hz

Standard

FPM

D1VW006MNGW

006

2 positions, operated in position 0, spring offset in position a

205 (DC)

Standard

NBR

D1VW006MNJW

006

2 positions, operated in position 0, spring offset in position a

24 (DC)

Standard

NBR

D1VW006MNJWT

006

2 positions, operated in position 0, spring offset in position a

24 (DC)

Without manual override

NBR

D1VW006MNYW

006

2 positions, operated in position 0, spring offset in position a

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW007CNGW

007

3 positions, spring offset in position 0, operated in position a or b

205 (DC)

Standard

NBR

D1VW007CNJW

007

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Standard

NBR

D1VW007CNKW

007

3 positions, spring offset in position 0, operated in position a or b

12 (DC)

Standard

NBR

D1VW007CNTW

007

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW007CNUW

007

3 positions, spring offset in position 0, operated in position a or b

98 (DC)

Standard

NBR

D1VW007CNYW

007

3 positions, spring offset in position 0, operated in position a or b

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW007ENJW

007

2 positions, spring offset in position 0, operated in position a

24 (DC)

Standard

NBR

D1VW007KNJW

007

2 positions, spring offset in position 0, operated in position b

24 (DC)

Standard

NBR

D1VW007KNKW

007

2 positions, spring offset in position 0, operated in position b

12 (DC)

Standard

NBR

D1VW007MNJW

007

2 positions, operated in position 0, spring offset in position a

24 (DC)

Standard

NBR

D1VW008CNGW

008

3 positions, spring offset in position 0, operated in position a or b

205 (DC)

Standard

NBR

D1VW008CNGW4N

008

3 positions, spring offset in position 0, operated in position a or b

205 (DC)

With lockable manual override

NBR

D1VW008CNGWS2

008

3 positions, spring offset in position 0, operated in position a or b

205 (DC)

Soft shift

NBR

D1VW008CNGWS3

008

3 positions, spring offset in position 0, operated in position a or b

205 (DC)

Soft shift

NBR

D1VW008CNJEE

008

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW008CNJW

008

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Standard

NBR

D1VW008CNJW4N

008

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

With lockable manual override

NBR

D1VW008CNJWS2

008

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Soft shift

NBR

D1VW008CNJWS3

008

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Soft shift

NBR

D1VW008CNJWT

008

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Without manual override

NBR

D1VW008CNKW

008

3 positions, spring offset in position 0, operated in position a or b

12 (DC)

Standard

NBR

D1VW008CNKWS2

008

3 positions, spring offset in position 0, operated in position a or b

12 (DC)

Soft shift

NBR

D1VW008CNKWS3

008

3 positions, spring offset in position 0, operated in position a or b

12 (DC)

Soft shift

NBR

D1VW008CNNEE

008

3 positions, spring offset in position 0, operated in position a or b

230 (AC), 50 (Hz)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW008CNPEE

008

3 positions, spring offset in position 0, operated in position a or b

110 (AC), 50 Hz

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW008CNTW

008

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW008CNTWT

008

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Without manual override

NBR

D1VW008CNUW

008

3 positions, spring offset in position 0, operated in position a or b

98 (DC)

Standard

NBR

D1VW008CNYW

008

3 positions, spring offset in position 0, operated in position a or b

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW008CVJEE

008

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

FPM

D1VW008CVJW

008

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Standard

FPM

D1VW008CVKW

008

3 positions, spring offset in position 0, operated in position a or b

12 (DC)

Standard

FPM

D1VW008CVNEE

008

3 positions, spring offset in position 0, operated in position a or b

230 (AC), 50 (Hz)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

FPM

D1VW008CVTW

008

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Standard

FPM

D1VW008CVYW

008

3 positions, spring offset in position 0, operated in position a or b

110/120 (AC), 50/60 Hz

Standard

FPM

D1VW008ENGW

008

2 positions, spring offset in position 0, operated in position b

205 (DC)

Standard

NBR

D1VW008ENJEE

008

2 positions, spring offset in position 0, operated in position b

24 (DC)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW008ENJW

008

2 positions, spring offset in position 0, operated in position b

24 (DC)

Standard

NBR

D1VW008ENJW4N

008

2 positions, spring offset in position 0, operated in position b

24 (DC)

With lockable manual override

NBR

D1VW008ENJWS2

008

2 positions, spring offset in position 0, operated in position b

24 (DC)

Soft shift

NBR

D1VW008ENJWS3

008

2 positions, spring offset in position 0, operated in position b

24 (DC)

Soft shift

NBR

D1VW008ENKW

008

2 positions, spring offset in position 0, operated in position b

12 (DC)

Standard

NBR

D1VW008ENNEE

008

2 positions, spring offset in position 0, operated in position b

230 (AC), 50 (Hz)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW008ENTW

008

2 positions, spring offset in position 0, operated in position b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW008ENYW

008

2 positions, spring offset in position 0, operated in position b

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW008EVJW

008

2 positions, spring offset in position 0, operated in position b

24 (DC)

Standard

FPM

D1VW008EVJWS2

008

2 positions, spring offset in position 0, operated in position b

24 (DC)

Soft shift

FPM

D1VW008FNJW

008

2 positions, operated in position 0, spring offset in position a

24 (DC)

Standard

NBR

D1VW008FNYW

008

2 positions, operated in position 0, spring offset in position a

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW008KNGW

008

2 positions, spring offset in position 0, operated in position a

205 (DC)

Standard

NBR

D1VW008KNJEE

008

2 positions, spring offset in position 0, operated in position a

24 (DC)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW008KNJW

008

2 positions, spring offset in position 0, operated in position a

24 (DC)

Standard

NBR

D1VW008KNJWS2

008

2 positions, spring offset in position 0, operated in position a

24 (DC)

Soft shift

NBR

D1VW008KNJWS3

008

2 positions, spring offset in position 0, operated in position a

24 (DC)

Soft shift

NBR

D1VW008KNKW

008

2 positions, spring offset in position 0, operated in position a

12 (DC)

Standard

NBR

D1VW008KNTW

008

2 positions, spring offset in position 0, operated in position a

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW008KNUW

008

2 positions, spring offset in position 0, operated in position a

98 (DC)

Standard

NBR

D1VW008KNYW

008

2 positions, spring offset in position 0, operated in position a

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW008KVJW

008

2 positions, spring offset in position 0, operated in position a

24 (DC)

Standard

FPM

D1VW008MNJW

008

2 positions, operated in position 0, spring offset in position b

24 (DC)

Standard

NBR

D1VW008MNKW

008

2 positions, operated in position 0, spring offset in position b

12 (DC)

Standard

NBR

D1VW008MNTW

008

2 positions, operated in position 0, spring offset in position b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW009CNGW

009

3 positions, spring offset in position 0, operated in position a or b

205 (DC)

Standard

NBR

D1VW009CNGWS3

009

3 positions, spring offset in position 0, operated in position a or b

205 (DC)

Soft shift

NBR

D1VW009CNJEE

009

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW009CNJW

009

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Standard

NBR

D1VW009CNJW4N

009

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

With lockable manual override

NBR

D1VW009CNJWS2

009

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Soft shift

NBR

D1VW009CNJWS3

009

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Soft shift

NBR

D1VW009CNJWT

009

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Without manual override

NBR

D1VW009CNKW

009

3 positions, spring offset in position 0, operated in position a or b

12 (DC)

Standard

NBR

D1VW009CNKWS3

009

3 positions, spring offset in position 0, operated in position a or b

12 (DC)

Soft shift

NBR

D1VW009CNNEE

009

3 positions, spring offset in position 0, operated in position a or b

230 (AC), 50 (Hz)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW009CNPEE

009

3 positions, spring offset in position 0, operated in position a or b

110 (AC), 50 (Hz)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW009CNTW

009

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW009CNUW

009

3 positions, spring offset in position 0, operated in position a or b

98 (DC)

Standard

NBR

D1VW009CNYW

009

3 positions, spring offset in position 0, operated in position a or b

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW009CVJEE

009

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

FPM

D1VW009CVJW

009

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Standard

FPM

D1VW009CVTW

009

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Standard

FPM

D1VW009ENJEE

009

2 positions, spring offset in position 0, operated in position b

24 (DC)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW009ENJW

009

2 positions, spring offset in position 0, operated in position b

24 (DC)

Standard

NBR

D1VW009ENJW4N

009

2 positions, spring offset in position 0, operated in position b

24 (DC)

With lockable manual override

NBR

D1VW009ENKW

009

2 positions, spring offset in position 0, operated in position b

12 (DC)

Standard

NBR

D1VW009ENTW

009

2 positions, spring offset in position 0, operated in position b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW009ENYW

009

2 positions, spring offset in position 0, operated in position b

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW009EVJW

009

2 positions, spring offset in position 0, operated in position b

24 (DC)

Standard

FPM

D1VW009EVKWS3

009

2 positions, spring offset in position 0, operated in position b

12 (DC)

Soft shift

FPM

D1VW009FNJEE

009

2 positions, operated in position 0, spring offset in position a

24 (DC)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW009FNJW

009

2 positions, operated in position 0, spring offset in position a

24 (DC)

Standard

NBR

D1VW009FNJWT

009

2 positions, operated in position 0, spring offset in position a

24 (DC)

Without manual override

NBR

D1VW009FNKW

009

2 positions, operated in position 0, spring offset in position a

12 (DC)

Standard

NBR

D1VW009KNGW

009

2 positions, spring offset in position b, operated in position a

205 (DC)

Standard

NBR

D1VW009KNJW

009

2 positions, spring offset in position 0, operated in position a

24 (DC)

Standard

NBR

D1VW009KNJW4N

009

2 positions, spring offset in position 0, operated in position a

24 (DC)

With lockable manual override

NBR

D1VW009KNJWS2

009

2 positions, spring offset in position 0, operated in position a

24 (DC)

Soft shift

NBR

D1VW009KNKW

009

2 positions, spring offset in position 0, operated in position a

12 (DC)

Standard

NBR

D1VW009KNTW

009

2 positions, spring offset in position 0, operated in position a

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW009KNUW

009

2 positions, spring offset in position 0, operated in position a

98 (DC)

Standard

NBR

D1VW009KNYW

009

2 positions, spring offset in position 0, operated in position a

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW010CNJEE

010

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Explosion proof solenoids Ex e mb II T4Gb + IECEx conformity

NBR

D1VW010CNJW

010

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Standard

NBR

D1VW010CNJW4N

010

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

With lockable manual override

NBR

D1VW010CNJWT

010

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Without manual override

NBR

D1VW010CNTW

010

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW010CNYW

010

3 positions, spring offset in position 0, operated in position a or b

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW010CVTW

010

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Standard

FPM

D1VW010ENJW

010

2 positions, spring offset in position 0, operated in position a

24 (DC)

Standard

NBR

D1VW010ENTW

010

2 positions, spring offset in position 0, operated in position a

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW010ENUW

010

2 positions, spring offset in position 0, operated in position a

98 (DC)

Standard

NBR

D1VW010EVJW

010

2 positions, spring offset in position 0, operated in position a

24 (DC)

Standard

FPM

D1VW010FNJW

010

2 positions, operated in position 0, spring offset in position b

24 (DC)

Standard

NBR

D1VW010KNJW

010

2 positions, spring offset in position 0, operated in position b

24 (DC)

Standard

NBR

D1VW010KNJWS2

010

2 positions, spring offset in position 0, operated in position b

24 (DC)

Soft shift

NBR

D1VW010MNJW

010

2 positions, operated in position 0, spring offset in position a

24 (DC)

Standard

NBR

D1VW010MNJWT

010

2 positions, operated in position 0, spring offset in position a

24 (DC)

Without manual override

NBR

D1VW011CNGW

011

3 positions, spring offset in position 0, operated in position a or b

205 (DC)

Standard

NBR

D1VW011CNGWS3

011

3 positions, spring offset in position 0, operated in position a or b

205 (DC)

Soft shift

NBR

D1VW011CNJW

011

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Standard

NBR

D1VW011CNJWS2

011

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Soft shift

NBR

D1VW011CNJWS3

011

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Soft shift

NBR

D1VW011CNJWT

011

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Without manual override

NBR

D1VW011CNKW

011

3 positions, spring offset in position 0, operated in position a or b

12 (DC)

Standard

NBR

D1VW011CNTW

011

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW011CNUW

011

3 positions, spring offset in position 0, operated in position a or b

98 (DC)

Standard

NBR

D1VW011CNYW

011

3 positions, spring offset in position 0, operated in position a or b

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW011CVGWS2

011

3 positions, spring offset in position 0, operated in position a or b

205 (DC)

Soft shift

FPM

D1VW011CVGWS3

011

3 positions, spring offset in position 0, operated in position a or b

205 (DC)

Soft shift

FPM

D1VW011CVJW

011

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Standard

FPM

D1VW011CVJWS2

011

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Soft shift

FPM

D1VW011CVJWS3

011

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Soft shift

FPM

D1VW011CVTW

011

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Standard

FPM

D1VW011CVUW

011

3 positions, spring offset in position 0, operated in position a or b

98 (DC)

Standard

FPM

D1VW011ENJW

011

2 positions, spring offset in position 0, operated in position a

24 (DC)

Standard

NBR

D1VW011ENKW

011

2 positions, spring offset in position 0, operated in position a

12 (DC)

Standard

NBR

D1VW011ENTW

011

2 positions, spring offset in position 0, operated in position a

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW011ENYW

011

2 positions, spring offset in position 0, operated in position a

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW011EVJW

011

2 positions, spring offset in position 0, operated in position a

24 (DC)

Standard

FPM

D1VW011FNJW

011

2 positions, operated in position 0, spring offset in position b

24 (DC)

Standard

NBR

D1VW011KNJW

011

2 positions, spring offset in position 0, operated in position b

24 (DC)

Standard

NBR

D1VW011KNTW

011

2 positions, spring offset in position 0, operated in position b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW014CNJW

014

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Standard

NBR

D1VW014CNJWS2

014

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Soft shift

NBR

D1VW014CNKW

014

3 positions, spring offset in position 0, operated in position a or b

12 (DC)

Standard

NBR

D1VW014CNTW

014

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW014CNYW

014

3 positions, spring offset in position 0, operated in position a or b

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW014CVJW

014

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Standard

FPM

D1VW014ENJW

014

2 positions, spring offset in position 0, operated in position a

24 (DC)

Standard

NBR

D1VW014ENTW

014

2 positions, spring offset in position 0, operated in position a

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW014ENYW

014

2 positions, spring offset in position 0, operated in position a

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW014FNJW

014

2 positions, operated in position 0, spring offset in position b

24 (DC)

Standard

NBR

D1VW014KNGW

014

2 positions, spring offset in position 0, operated in position b

205 (DC)

Standard

NBR

D1VW014KNJW

014

2 positions, spring offset in position 0, operated in position b

24 (DC)

Standard

NBR

D1VW014KNJWS3

014

2 positions, spring offset in position 0, operated in position b

24 (DC)

Soft shift

NBR

D1VW014KNTW

014

2 positions, spring offset in position 0, operated in position b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW014KVTW

014

2 positions, spring offset in position 0, operated in position b

230/240 (AC), 50/60 Hz

Standard

FPM

D1VW015CNJW

015

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Standard

NBR

D1VW015CNJW4N

015

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

With lockable manual override

NBR

D1VW015CNJWS3

015

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Soft shift

NBR

D1VW015CNKW

015

3 positions, spring offset in position 0, operated in position a or b

12 (DC)

Standard

NBR

D1VW015CNTW

015

3 positions, spring offset in position 0, operated in position a or b

230/240 (AC), 50/60 Hz

Standard

NBR

D1VW015CNUW

015

3 positions, spring offset in position 0, operated in position a or b

98 (DC)

Standard

NBR

D1VW015CNYW

015

3 positions, spring offset in position 0, operated in position a or b

110/120 (AC), 50/60 Hz

Standard

NBR

D1VW015CVJW

015

3 positions, spring offset in position 0, operated in position a or b

24 (DC)

Standard

FPM